[Complete congenital atrioventricular block. Prenatal diagnosis and perinatal management].
Açar sözlər
Mücərrəd
OBJECTIVE
To describe our experience in prenatal diagnosis and perinatal management of congenital atrioventricular heart block, as well as pacemaker treatment in the neonate.
METHODS
A total of 13 fetuses are included. The diagnosis of atrioventricular dissociation was established by Doppler heart rate sample in the right atrium to show the atrial activity while the sample in the Aorta reflected the ventricular heart rate. Gestational age at diagnosis, ventricular heart rates, autoimmune maternal pathology, maternal blood tests for autoantibodies antiRo+, congenital structural heart disease, fetal hydrops, maternal medical treatment, perinatal results and pacemaker neonatal implantation are described.
RESULTS
Gestational age at diagnosis ranged between 22 and 32 (mean 27.6) weeks. Ventricular heart rates ranged between 32 to 80 (mean 54) beats/min. AntiRo+ antibodies were detected in 5 mothers, and clinical systemic lupus erythematosus was found in only one. Four had congenital heart disease (2 ventricular inversion and corrected TGA, 1 complete atrio-ventricular canal and 1 tricuspid atresia). Signs of heart failure and hydrops were detected in 9 fetuses. Treatment with beta-metasona and ritodrine was administered to 7 mothers when the ventricular heart rate dropped below 60 beats/min. Intrauterine fetal death occurred in 3 fetuses with structural congenital heart disease and hydrops. Delivery was performed by cesarean section in 8 preterm fetuses (one them a twins), 3 spontaneous deliveries at term and 3 stillbirth. Postnatal pacemaker implantation was carried out in 9 newborns (3 cases with unicameral temporal right ventricle electrode and 6 cases with permanent bicameral electrodes implanted through the subclavian vein and DDD pacemaker). Follow-up of the bicameral pacemaker group was satisfactory.
CONCLUSIONS
Persistent fetal bradycardia is the first sign to diagnose prenatal complete atrioventricular heart block. Echocardiography asses fetal haemodynamic status and may detect signs of fetal deterioration. Hydrops and further drop in the ventricular heart rate warrant urgent cesarean section and pacemaker management of the newborn.