Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

PEEP Mask for TBM-Induced Cough

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
СтатусЯшчэ не завербаваны
Спонсары
Duke University

Ключавыя словы

Рэферат

This study aims to determine if an expiratory resistance device that delivers non-invasive positive expiratory pressure (nPEP) will reduce or stop coughing, reduce airway resistance and improve quality of life in patients with tracheobronchomalacia (TBM) who are not candidates for tracheal stenting.

Апісанне

PROSPECTIVE:

Ten subjects with chronic cough and TBM diagnosed by bronchoscopy or computed tomography (CT) scan will be recruited. Comorbid conditions that can cause chronic cough, such as asthma, COPD, and GERD, must be treated if present, for subjects to qualify. At the pre-baseline visit (V-1), after obtaining written informed consent, each subject will complete validated cough questionnaires to quantify their cough severity and cough-related QOL at baseline. The baseline visit (V1) will occur approximately two weeks later, after a run-in period to minimize observation bias related to the cough questionnaires. At V1, the cough questionnaires will be repeated and subjects' airway resistance and reactance will be measured with impulse oscillometry (IOS). Subjects will then be given the nPEP device by the study team and instructed on its use. Approximately two weeks after device delivery, at the follow-up visit (V2), cough questionnaires and IOS will be repeated and they will be asked for feedback regarding device design and user experience. Subjects may then be entered into a cohort for up to six additional months, during which there will be no study visits or procedures, but subjects may be contacted by investigators for additional narrative feedback on the device and its use.

Study subjects will be given an nPEP device to use for two weeks. During this time participants will be asked to remain on their current medical regimen and not to make any dose changes or add new drugs, unless indicated by their primary care provider. Impulse oscillometry will be measured at V1 and 2 weeks later at V2 to assess effect of the nPEP device on airway physiology.

RETROSPECTIVE:

This device was tried on two individuals and it was initiative and was beneficial. Many patients are not candidates for tracheobronchoplasty itself due to medical comorbidities, prefer to avoid the associated risks, or are not candidates for the required tracheal stenting due to trachea size or anatomy. These patients are left without a viable therapeutic option for their severe cough.

Continuous positive airway pressure (CPAP) devices have been reported to stop or prevent cough in TBM, presumably through pneumatic stenting the large airways to maintain their patency during exhalation. CPAP devices, however, are not labeled for this indication and their functional utility is very limited given size of the device, need for a power source, and multiple steps to don the equipment that are not easily completed while actively and uncontrollably coughing.

The physicians aimed to provide positive airway pressure at a low cost and through readily accessible means, in order to abort coughing paroxysms in patients who were not candidates for tracheal stenting and did not have access to commercial CPAP devices. Patients at Duke University Hospital referred to the Interventional Pulmonary service for evaluation of severe, debilitating TBM-related cough and possible tracheal stenting, but who were not candidates for tracheal stenting given their airway anatomy, were given positive end expiratory pressure (PEEP) masks assembled using existing hospital supplies. Specifically, a standard, adjustable (5-20 cm H2O) positive end expiratory pressure (PEEP) valve manufactured for attachment to a manual resuscitation (commonly known as bag-valve-mask) device was attached directly to a flexible face mask, also from a manual resuscitation device. Patients were instructed by their physicians how to use the PEEP masks. The patients used the PEEP mask immediately during their clinical encounter and were given a mask to take home. (The device was created by fellow, Lindsay Boole.)

This was a limited intervention for a very small number of patients (two), specifically identified as being referred to Duke Interventional Pulmonary service with severe cough related to TBM, but with anatomy that ruled them out as candidates for tracheal stenting. There were no formal data collected and no separate follow-up for the purpose of this project (though patients had ongoing clinical follow-up per standard of care). The patients' subjective improvement with the masks was submitted as a case report abstract and poster at the American College of Chest Physician meeting in 2017.

Other physicians asked Dr. Boole about the mask and if it could be used for their patients. Therefore, the investigators would like to request a retrospective review of all patients that used the PEEP mask between January 1, 2009 and August 20, 2019 to be included in this pilot study. Approximately 15 records will be reviewed.

Даты

Апошняя праверка: 09/30/2019
Упершыню прадстаўлена: 11/13/2019
Меркаваная колькасць заявак прадстаўлена: 11/17/2019
Першае паведамленне: 11/18/2019
Апошняе абнаўленне адпраўлена: 04/23/2020
Апошняе абнаўленне апублікавана: 04/26/2020
Фактычная дата пачатку даследавання: 06/30/2020
Разліковая дата першаснага завяршэння: 06/30/2021
Разліковая дата завяршэння даследавання: 06/30/2021

Стан альбо хвароба

Tracheobronchomalacia

Ўмяшанне / лячэнне

Device: nPEP Recipients

Фаза

-

Групы ўзбраенняў

РукаЎмяшанне / лячэнне
Experimental: nPEP Recipients
Single-patient, adjustable expiratory resistance device that provides positive pressure (5 to 20 cm H2O) during expiration
Device: nPEP Recipients
Positive end expiratory pressure (PEEP) mask

Крытэрыі прыдатнасці

Узрост, які мае права на вучобу 18 Years Каб 18 Years
Пол, прыдатны для навучанняAll
Прымае здаровых валанцёраўТак
Крытэрыі

Inclusion Criteria:

- Age ≥18 years

- Chronic cough for at least 8 weeks

- Visualization of ≥50% collapse of the trachea or mainstem bronchus on CT scan or bronchoscopy

- No upper or lower respiratory infection within 4 weeks

- Negative evaluation or treatment response for cough:

- Asthma (negative spirometry or treatment with oral corticosteroids or ≥moderate dose of inhaled corticosteroids)

- Gastroesophageal reflux disease (GERD) (negative potential hydrogen (pH) probe or treatment with proton pump inhibitor)

- Upper airway disease (nasal or oral corticosteroids, antihistamines)

- Chronic Obstructive Pulmonary Disease (COPD) (negative spirometry or treatment with triple-inhaled therapy [≥moderate dose of inhaled corticosteroids, long-acting muscarinic antagonist, and long-acting beta agonist])

- Having capacity to provide legal written informed consent

Exclusion Criteria:

- History of tracheobronchoplasty or chronic tracheal stenting

- Current tracheostomy

- History of external chest trauma

- History of mediastinal goiter

- Current smoking within 6 months

- Current use of angiotensin-converting enzyme (ACE) inhibitor within 6 weeks

- Primary parenchymal lung disease

- History of:

- Sarcoidosis

- Interstitial lung disease

- Chronic mycobacterial infection

- Lung cancer

- Lung transplantation

- Unstable congestive heart failure

- History of spontaneous pneumothorax

- Other medical conditions that interfere with participation in the study

Вынік

Першасныя вынікі

1. Change in cough severity as measured by the Cough-Visual Analog Scale [Pre-baseline, baseline, two weeks]

The primary objective is to determine if use of the nPEP device will change cough severity. Responses to the Cough-Visual Analog Scale range from 0-100 mm, with higher scores corresponding to worse outcomes.

2. Change in quality of life as measured by the Cough-Specific Quality-of-Life Questionnaire [Pre-baseline, baseline, two weeks]

The objective is to determine if use of the nPEP device will change cough-related quality of life. Responses to the Cough-Specific Quality-of-Life Questionnaire range from 28-112, with higher scores corresponding to worse outcomes.

3. Change in quality of life as measured by the Leicester Cough Questionnaire [Pre-baseline, baseline, two weeks]

The objective is to determine if use of the nPEP device will change cough-related quality of life. Responses to the Leicester Cough Questionnaire range from 19-133, with lower scores corresponding to worse outcomes.

Меры другаснага выніку

1. Change in proximal airway resistance as assessed by impulse oscillometry [Baseline, two weeks]

The secondary objective is to determine if use of the nPEP device changes airway physiology, specifically proximal airway resistance, as assessed by impulse oscillometry.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge