Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Archives of internal medicine 2004-Jan

Accuracy of ultrasonography in predicting celiac disease.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
Mirella Fraquelli
Agostino Colli
Alice Colucci
Maria Teresa Bardella
Cristina Trovato
Roberta Pometta
Michela Pagliarulo
Dario Conte

Ключавыя словы

Рэферат

BACKGROUND

Various ultrasonographic (US) signs have been reported in overt celiac disease (CD). The aim of this study was to investigate the diagnostic accuracy of 6 US parameters in predicting CD.

METHODS

One hundred sixty-two consecutive patients with chronic diarrhea (n=105), iron deficiency anemia (n=25), or dyspepsia (n=32) underwent anti-endomysial IgA antibody determination and duodenal biopsy. Moreover, US evaluation of 6 parameters (ie, fasting gallbladder volume, transverse diameter of small bowel loops, thickness of the small bowel wall, pattern of peristalsis, presence of free abdominal fluid, and diameter of the mesenteric lymph nodes) was done by 2 operators blind to the serological and histological findings. The pretest probability of CD was estimated to be between 5% and 10%. The percentage of agreement between US and histologic findings, the sensitivity, specificity, positive and negative likelihood ratios, and the posttest probability for positive and negative results were calculated.

RESULTS

Celiac disease was diagnosed in 12 patients (7.4%). An increased gallbladder volume, the presence of free fluid in the abdominal cavity, and enlarged mesenteric lymph nodes showed a specificity of 96%, 96%, and 97%, respectively (95% confidence intervals [CIs], 92%-99%, 93%-99%, and 95%-99%), whereas the presence of dilated small bowel loops with increased fluid content and increased peristalsis had a sensitivity of 92% and 83%, respectively (95% CIs, 76%-100% and 62%-100%). Eleven (92%) of the 12 patients with celiac disease and 35 (23%) of the 150 patients who did not have the disease had at least 1 US sign (P=.001); all of the US signs were concomitantly present in 4 patients with CD (33%) and 1 patient without CD (0.6%) (P=.001).

CONCLUSIONS

Ultrasonographic evaluation can accurately predict CD but its place in the diagnostic algorithm depends upon the probability of the disease in the considered population.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge