Belarusian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Lens and eye toxicity research 1990

Ocular digitalis effects in normal subjects.

Перакладаць артыкулы могуць толькі зарэгістраваныя карыстальнікі
Увайсці / Зарэгістравацца
Спасылка захоўваецца ў буферы абмену
G Duncker
H Krastel

Ключавыя словы

Рэферат

Several visual functions were examined before and during self-application of therapeutic doses of digitoxin. The ERG recordings showed a reduction of the critical flicker fusion frequency from 70 Hz to 35-40 Hz. Recovery of color vision after macular photostress was examined with Nagel's anomaloscope and Jaeger's tritanomaloscope. After digitoxin intake the matching range at the tritanomaloscope was enlarged. Following macular photostress the recovery time of both the Rayleigh and the Trendelenburg matches was significantly prolonged. The mesoptometer readings did not show any changes during the application of digitalis. This demonstrates that the process of neural adaptation is intact during digitoxin therapy. The error score in the Lanthony desaturated 15 panel test was slightly increased after digitalis application. The Farnsworth-Munsell 100-hue test showed a marked increase in the total error score. There were no changes in the standard panel D-15. The Ishihara pseudoisochromatic plates were read without mistakes after digitalis medication. The chromatic visual acuity for red-green and blue was examined by recording the maximum reading distance for the Velhagen pseudoisochromatic plates "65" (Jaeger's test) and "49". For both plates the reading distance was reduced by 50% during digitoxin therapy. Computerized perimetry by colored stimuli (Tübingen Automatic Perimeter by Aulhorn and Durst) did not reveal any definitive changes in sensitivity thresholds with therapeutic serum levels of digitalis. Spectral increment sensitivity for the isolated blue cone system (Wald-Marré approach) was not influenced by therapeutic doses of digitoxin. Topical digitoxin application (0.02 mg/10 ml) did not interfere with the pupillary light reflex (infrared pupillography) or with the accommodative amplitude or intraocular pressure. It did, however, result in toxic keratopathy with swelling of endothelial cells and edema of the corneal stroma and epithelium. All changes disappeared after withdrawal of digitalis.

Далучайцеся да нашай
старонкі ў facebook

Самая поўная база дадзеных пра лекавыя травы, падтрыманая навукай

  • Працуе на 55 мовах
  • Лячэнне травой пры падтрымцы навукі
  • Распазнаванне траў па малюнку
  • Інтэрактыўная GPS-карта - пазначце травы па месцы (хутка)
  • Чытайце навуковыя публікацыі, звязаныя з вашым пошукам
  • Шукайце лекавыя зёлкі па іх уздзеянні
  • Арганізуйце свае інтарэсы і будзьце ў курсе навінавых даследаванняў, клінічных выпрабаванняў і патэнтаў

Увядзіце сімптом альбо захворванне і прачытайце пра зёлкі, якія могуць дапамагчы, набярыце траву і паглядзіце хваробы і сімптомы, супраць якіх яна выкарыстоўваецца.
* Уся інфармацыя заснавана на апублікаваных навуковых даследаваннях

Google Play badgeApp Store badge