Evaluation of Bond Strength and Microleakage of a Novel Metal-titanate Antibacterial Agent.
Ключови думи
Резюме
OBJECTIVE
To evaluate the effect on both bond strength and microleakage of incorporation of a novel antibacterial nanoparticulate metal-titanate complex (nMT) into a dental adhesive system.
METHODS
Eighty extracted human molars were prepared to determine whether incorporation of nMT into bonding agents can affect shear bond strength (SBS) and adhesive strength fatigue. SBS was measured with a universal testing machine, and the peak force at failure was recorded. An electromechanical fatigue machine was used for cyclic loading treatment of specimens. Differences in the SBS values among groups were identified using analysis of variance and Tukey post hoc analyses (α=0.05). Twenty standard Class V cavities were restored to examine microleakage when the primer/bonding resin was modified with 10 wt% nMT. Microleakage at the enamel and dentin margins was calculated as a percentage of the full length of the cavity. Results of the microleakage experiment were analyzed with paired and independent sample t-tests (α=0.05).
RESULTS
The mean (± standard deviation) shear bond strength values of before fatigue and after fatigue ranged from 21.9 (2.5) MPa to 23.9 (3.8) MPa and from 17.1 (2.5) MPa to 17.7 (2.5) MPa respectively. No statistically significant differences in failure force were observed among groups (p=0.70). Microleakage under all conditions was significantly greater in the dentin margins than in the enamel margins (p<0.05). There was no evidence that microleakage differed between the experimental groups with modified primer and bonding resin.
CONCLUSIONS
Incorporating nMT into a dental adhesive system will not compromise the resin composite's tooth bonding and sealing ability.