Viszeralmedizin 2014-Feb

What Influences the Quality of Prevention Colonoscopy?

Samo registrirani korisnici mogu prevoditi članke
Prijavite se / prijavite se
Veza se sprema u međuspremnik
Wolfgang Schmidt-Tänzer
Axel Eickhoff

Ključne riječi

Sažetak

BACKGROUND

Colorectal cancer still has a high incidence and mortality. Although colonoscopy is considered as gold standard of colorectal cancer screening, there still exists an unsatisfactory level of adenomas missed in screening and surveillance colonoscopy. Furthermore, patients bear the burden of potentially unpleasant and painful examination and preparation procedures.

METHODS

A search of the literature using PubMed was carried out, supplemented by a review of the programs of the Digestive Disease Week (DDW) and the United European Gastroenterology Week (UEGW) 2011-2013.

RESULTS

Several new approaches to colonoscopy were described: water, CO2 and cap colonoscopy, and application of spasmolytics such as hyoscine butylbromide and glucagon. The use of these methods does not necessitate the purchase of new endoscopes. They are feasible and safe, facilitate achieving the aim of more comfort and less pain, and perhaps allow lower doses of sedatives to be used. However, a clear effect on procedure time is lacking. Furthermore, the published data do not consistently answer the question of whether these techniques have a positive impact on the most important goal, the better detection of carcinoma precursors.

CONCLUSIONS

More efforts to optimize bowel preparation have to be made to improve visualization of the mucosal surface. The most reliable criteria for the quality of screening and surveillance colonoscopy remain a minimum cecal intubation rate of >90%, a withdrawal time of at least 6 or better 9 min, and an adenoma detection rate of >20%. These results should be achieved with a complication rate lower than 1%, including polypectomy.

Pridružite se našoj
facebook stranici

Najkompletnija baza ljekovitog bilja potpomognuta naukom

  • Radi na 55 jezika
  • Biljni lijekovi potpomognuti naukom
  • Prepoznavanje biljaka po slici
  • Interaktivna GPS karta - označite bilje na lokaciji (uskoro)
  • Pročitajte naučne publikacije povezane sa vašom pretragom
  • Pretražite ljekovito bilje po učincima
  • Organizirajte svoja interesovanja i budite u toku sa istraživanjem vijesti, kliničkim ispitivanjima i patentima

Upišite simptom ili bolest i pročitajte o biljkama koje bi mogle pomoći, unesite travu i pogledajte bolesti i simptome protiv kojih se koristi.
* Sve informacije temelje se na objavljenim naučnim istraživanjima

Google Play badgeApp Store badge