Catalan
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

Blood Volume Analysis and Related Outcomes in Hemodialysis

Només els usuaris registrats poden traduir articles
Inicieu sessió / registreu-vos
L'enllaç es desa al porta-retalls
EstatCompletat
Patrocinadors
VA New York Harbor Healthcare System
Col·laboradors
Daxor Corporation

Paraules clau

Resum

An understanding of fluid changes that occur during hemodialysis (HD) with ultrafiltration (UF) is essential for determining the efficacy of HD, as well as for reducing complications related to hypovolemia or, conversely, chronic volume overload.

Descripció

Background: Accurate assessment of the BV and distribution of body fluids is essential for prescribing HD and for reducing complications related to hypovolemia and volume overload. Monitoring relative changes in BV using hematocrit (Hct), e.g. CLM-III, an indirect method, cannot be used to determine the absolute levels of BV. Here we report the first study of isotope BV measurement (IBVM) for assessing volume status in HD patients using indicator dilutional method.

10 adult HD patients were enrolled in this prospective observational study. Multi-point IBVM before and after HD was performed using BVA-100 (Daxor, New York, NY). BVA-100 calculates BV with an accuracy of ±2.5%, by using <25μCi of iodinated I-131 albumin. It assumes normal BV for a given individual on the basis of patients' deviation from ideal body weight. Fluid loss from the extravascular component of the extracellular space (EV) was calculated by subtracting absolute BV change from total weight loss. Intradialytic relative BV changes were measured by CLM-III during the same HD session. Bland-Altman plot was used to compare relative BV change pre- and post-HD by IBVM and CLM-III.

Dates

Darrera verificació: 08/31/2012
Primer enviat: 08/30/2012
Inscripció estimada enviada: 08/30/2012
Publicat per primera vegada: 09/04/2012
Última actualització enviada: 09/05/2012
Publicació de l'última actualització: 09/09/2012
Data d'inici de l'estudi real: 12/31/2011
Data estimada de finalització primària: 04/30/2012
Data estimada de finalització de l’estudi: 04/30/2012

Condició o malaltia

End Stage Kidney Disease

Fase

-

Grups de braços

BraçIntervenció / tractament
Hemodialysis patients
Stable prevalent patients on 3-times-per-week hemodialysis

Criteris d'elegibilitat

Edats elegibles per estudiar 21 Years Per a 21 Years
Sexes elegibles per estudiarAll
Mètode de mostreigNon-Probability Sample
Accepta voluntaris saludables
Criteris

Inclusion Criteria:

- Age >21 years

- Primary diagnosis of either chronic or acute kidney disease

- Currently receiving HD treatment

- Thrice-weekly or twice-weekly HD schedule

- Treated with standard bicarbonate HD for at least the preceding 6 months

Exclusion Criteria:

- Pregnant women or nursing mothers

- Known hypersensitivity to iodine, eggs, albumin or any other component of the Volumex injection kit

- Current enrollment in another investigational treatment protocol for dialysis

- The need to perform hemodialysis with predilution because this will interfere with measurements of relative blood volume changes (ΔRBV)

- Kidney transplantation

- Malignancy requiring chemotherapy

- Unmeasurable blood pressure with a sphygmomanometer

- Active hematological disease

- Active gastrointestinal bleeding

- Severe malnutrition (predialysis serum albumin <2.6 g/dL)

- Persistent condition of intradialytic blood pressure instability (hypotensive episodes in >80% of regular dialysis sessions) within the previous one month period

Resultat

Mesures de resultats primaris

1. Blood volume measurement and comparison to Crit-Line reading [Six months]

To compare the results obtained by two different methods of assessing BV: direct measurement of BV using the Blood Volume Analyzer (BVA-100) vs. indirect measurement of relative changes in BV using the Crit-Line Monitor (CLM III). Blood volume is measured in liters and compared with "ideal blood volume" nomograms. Crit-Line Monitor measures relative change in blood volume as a percentage change and does not have absolute values.

Uneix-te a la nostra
pàgina de Facebook

La base de dades d’herbes medicinals més completa avalada per la ciència

  • Funciona en 55 idiomes
  • Cures a base d'herbes recolzades per la ciència
  • Reconeixement d’herbes per imatge
  • Mapa GPS interactiu: etiqueta les herbes a la ubicació (properament)
  • Llegiu publicacions científiques relacionades amb la vostra cerca
  • Cerqueu herbes medicinals pels seus efectes
  • Organitzeu els vostres interessos i estigueu al dia de les novetats, els assajos clínics i les patents

Escriviu un símptoma o una malaltia i llegiu sobre herbes que us poden ajudar, escriviu una herba i vegeu malalties i símptomes contra els quals s’utilitza.
* Tota la informació es basa en investigacions científiques publicades

Google Play badgeApp Store badge