Greek
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Annals of Clinical and Laboratory Science

Neonatal screening for biotinidase deficiency.

Μόνο εγγεγραμμένοι χρήστες μπορούν να μεταφράσουν άρθρα
Σύνδεση εγγραφή
Ο σύνδεσμος αποθηκεύεται στο πρόχειρο
D T Forman
D D Bankson
W E Highsmith

Λέξεις-κλειδιά

Αφηρημένη

Children with juvenile-onset multiple carboxylase deficiency lack biotinidase activity (biotinamide amidohydrolase, EC 3.5.1.12) in the liver and other tissues. Hence, little free biotin is metabolically available, resulting in seizures, acidosis, and serious neurological damage. As the absence of hepatic biotinidase activity is reflected in serum, assessment of biotinidase status can easily be made from a blood sample. A convenient qualitative procedure for screening infants has been employed in order to estimate serum levels of biotinidase in as little as 10 microliters of sample. This colorimetric procedure detects the formation of free p-aminobenzoate cleaved from the substrate, N-biotinyl-p-aminobenzoate at pH 6.0. The assay is easily performed and has a low incidence of false positive results. A kinetic assay for serum biotinidase has also been developed using biotinyl-p-nitroanilide (BpNA) as substrate. When 50 microliters of biotinidase positive serum was incubated with 0.2 mM BpNA in phosphate buffer at pH 6.0, an increase in absorbance was observed at 405 nm. The rate of change in absorbance was followed kinetically on the Roche Cobas BIO analyzer at 37 degrees C. Monitoring the increase in absorbance of para-nitroanilide every 60 seconds over 30 minutes demonstrated linearity from 10 to 30 minutes. In comparing results from this kinetic assay on 48 randomly selected sera with those obtained using a colorimetric procedure, a correlation coefficient of 0.85 was obtained. Several false positive results were observed in clearly lipemic sera.

Γίνετε μέλος της σελίδας
μας στο facebook

Η πληρέστερη βάση δεδομένων φαρμακευτικών βοτάνων που υποστηρίζεται από την επιστήμη

  • Λειτουργεί σε 55 γλώσσες
  • Βοτανικές θεραπείες που υποστηρίζονται από την επιστήμη
  • Αναγνώριση βοτάνων με εικόνα
  • Διαδραστικός χάρτης GPS - ετικέτα βότανα στην τοποθεσία (σύντομα)
  • Διαβάστε επιστημονικές δημοσιεύσεις που σχετίζονται με την αναζήτησή σας
  • Αναζήτηση φαρμακευτικών βοτάνων με τα αποτελέσματά τους
  • Οργανώστε τα ενδιαφέροντά σας και μείνετε ενημερωμένοι με την έρευνα ειδήσεων, τις κλινικές δοκιμές και τα διπλώματα ευρεσιτεχνίας

Πληκτρολογήστε ένα σύμπτωμα ή μια ασθένεια και διαβάστε για βότανα που μπορεί να βοηθήσουν, πληκτρολογήστε ένα βότανο και δείτε ασθένειες και συμπτώματα κατά των οποίων χρησιμοποιείται.
* Όλες οι πληροφορίες βασίζονται σε δημοσιευμένη επιστημονική έρευνα

Google Play badgeApp Store badge