English
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

Magnetic Resonance Technics for the Assessment of Liver Function Before and After TIPS

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
StatusRecruiting
Sponsors
West China Hospital

Keywords

Abstract

Portal hypertension is the end-stage fatal complications of liver cirrhosis. Decompensated cirrhosis patients can pass through transjugular intrahepatic portosystemic shunt to effectively prevent bleeding and refractory ascites. However, the occurrence of hepatic encephalopathy and liver function failure, infection, bleeding again are main lethality postoperative complications after TIPS. The accurate TIPS shunt is necessary to reduce the incidence of complications and improve the patients' survival rate and survival quality. Hepatic venous pressure gradient (HVPG) is standard to evaluate TIPS preoperative and postoperative hemodynamic change and is also the most important the predictors of decompensation and varicose vein bleeding of liver cirrhosis. Whether there is a kind of noninvasive monitoring method can guide TIPS accurate shunt and evaluate the prognosis of patients.
Magnetic resonance imaging (MRI) has a high soft tissue resolution, time and spatial resolution, abdominal MRI can noninvasively, dynamically detect the liver, spleen, portal system functions, the changes of portal system hemodynamics, blood supply of liver tissue, perfusion and liver cell function, etc.
In order to analyze the liver function and survival of liver cirrhosis patients after transjugular intrahepatic portosystemic shunt, advanced magnetic resonance techniques are used before and after transjugular intrahepatic portosystemic shunt. We will combine a variety of advanced magnetic resonance imaging technology, long-term and dynamic monitor TIPS preoperative and postoperative liver function, blood flow, perfusion, the change of tissue elasticity, and analysis the incidence of hepatic encephalopathy, hemorrhage, hepatic failure and survival rate with MRI changes. Finally, we will develop new prediction index, guide TIPS precision shunts, evaluate a variety of the value of imaging technology in the application of patients with TIPS to find the most sensitive technology, and discover the correlation between MRI function parameters with patient's survival. In order to analyze the liver function and survival of liver cirrhosis patients after transjugular intrahepatic portosystemic shunt, advanced magnetic resonance techniques are used to evaluate liver function, blood flow, elasticity, perfusion of before and after transjugular intrahepatic portosystemic shunt.

Description

Portal hypertension is the end-stage fatal complications of liver cirrhosis. Decompensated cirrhosis patients can pass through transjugular intrahepatic portosystemic shunt to effectively prevent bleeding and refractory ascites. However, the occurrence of hepatic encephalopathy and liver function failure, infection, bleeding again are main lethality postoperative complications after TIPS. The accurate TIPS shunt is necessary to reduce the incidence of complications and improve the patients' survival rate and survival quality. Hepatic venous pressure gradient (HVPG) is standard to evaluate TIPS preoperative and postoperative hemodynamic change and is also the most important the predictors of decompensation and varicose vein bleeding of liver cirrhosis. Whether there is a kind of noninvasive monitoring method can guide TIPS accurate shunt and evaluate the prognosis of patients.

Magnetic resonance imaging (MRI) has a high soft tissue resolution, time and spatial resolution, abdominal MRI can noninvasively, dynamically detect the liver, spleen, portal system functions, the changes of portal system hemodynamics, blood supply of liver tissue, perfusion and liver cell function, etc. Magnetic resonance 4D-flow imaging, can accurately measure the portal vein system blood vessels and shunt channels, blood volume, flow velocity parameters of blood flow can be detected. Recent studies have confirmed that the 4D-flow technology can accurately, long-term follow-up monitoring TIPS preoperative, postoperative portal vein blood flow, which have better sensitivity and more accurate than ultrasound to detect blood flow. Magnetic resonance perfusion imaging of the liver can quantitatively obtain liver tissue microcirculation status, monitor portal vein and hepatic artery blood perfusion, the liver perfusion has a significant correlation with Child-Pugh score and degree of liver fibrosis and cirrhosis of the liver. Compared with the traditional magnetic resonance imaging contrast agents, liver specific contrast agents have small renal toxicity, uptake by liver cell specificity, recent studies have found that magnetic resonance imaging with liver cell specificity contrast agents have significantly correlated with the stage of fibrosis of the liver and liver function, and has been used in the clinical staging of liver fibrosis and early detection of hepatocellular carcinoma (HCC). Magnetic resonance elastography (MRE) is a new imaging technology in recent years and a unique image method. As a noninvasive and quantitative method to detect elastic properties of the organ. Plenty of research results showed that in patients with liver cirrhosis, liver and spleen of elasticity have significant correlation with the degree of portal hypertension. So far, a variety of functional imaging methods grade and guide prognosis of patients with cirrhosis, which have been confirmed to have significant clinical value. MRE has been written for the latest diagnosis and treatment of portal hypertension guidelines.

In order to analyze the liver function and survival of liver cirrhosis patients after transjugular intrahepatic portosystemic shunt, advanced magnetic resonance techniques are used before and after transjugular intrahepatic portosystemic shunt. Researchers will combine a variety of advanced magnetic resonance imaging technology, long-term and dynamic monitor TIPS preoperative and postoperative liver function, blood flow, perfusion, the change of tissue elasticity, and analysis the incidence of hepatic encephalopathy, hemorrhage, hepatic failure and survival rate with MRI changes. Finally, Researchers will develop a new predictive index, guide TIPS precision shunts, evaluate a variety of the value of imaging technology in the application of patients with TIPS to find the most sensitive technology, and discover the correlation between MRI function parameters with patient's survival. In order to analyze the liver function and survival of liver cirrhosis patients after transjugular intrahepatic portosystemic shunt, advanced magnetic resonance techniques are used to evaluate liver function, blood flow, elasticity, perfusion of before and after transjugular intrahepatic portosystemic shunt.

Materials and Methods Patients Inclusion criteria: 18-75 years old; liver cirrhosis (diagnosis by imaging, laboratory examination, clinical symptoms and liver biopsy); history of endoscopy confirmed esophageal varicose vein hemorrhage (5 days or longer); the Child-Pugh, B or C less 13; willing to participate in this clinical study, and sign an Informed consent. Exclusion criteria: Child-Pugh ≥12 or MELD ≥18; non-cirrhotic portal hypertension (including regional portal hypertension); total bilirubin over 2 times upper; combined liver cancer or other malignant tumor; infection, uncontrolled sepsis, etc; There are other contraindications to TIPS, EVL and NSBB treatment; heart, lung, kidney and other organs severe disease; women during pregnancy or lactation.

The patients' information Basic information: name, age, gender, work, BMI, rural/urban; Past medical history: the presence of a stool and hemoptysis, ligation hemostasis under gastroscopy history; History of ascites; Hepatic encephalopathy history; Drugs make: diuretics, B-blocker; With or without cardiopulmonary dysfunction history. Cause: alcoholic liver cirrhosis; HBV/HCV related cirrhosis of the liver; AIH, PBC, others. TIPS surgery reason: gastrointestinal bleeding, ascites, other. TIPS postoperative complications: hepatic encephalopathy, ascites, varicose vein bleeding, kidney failure, liver failure. Before and after TIPS, 96 hours, 1 month, 3 months, 6 months and 12 months, then each half year to follow-up until to 5 years. Physical signs and symptoms, Child-Pugh score, MELD score, ammonia and platelet are collected. Before and after TIPS, 96 hours, 6 months and 12 months, multi parameters MRI is performed. MRI scan parameters: 4D-flow sequence: the respiratory gating and cardiac switch control, phase code acquisition of three- space, to obtain parameters of blood flow parameters mapping images. Imaging parameters: imaging volume, 32 × 32 ×24 cm2 to get the isotropic spatial resolution 1.25 mm. TR/TE: 6.4ms/2.2ms, Flip Angle: 16 °. Imaging time is about 12 minutes, depending on the respiratory gating. MRE: simple principle is on the basis of common MRI scans, install a non-magnetic voltage sensor on patients to produce mechanical vibration that transfer into tissues and organs. Particle produce displacement in the direction of propagation of mechanical vibration. The size of the displacement associated with the level of organization elasticity. Imaging parameters are as follows: 3.0 T MR (GE), 12 channels of the surface phased array coil, respiratory gating, single-shot spin echo planar imaging sequence with flow compensation movement encoding gradient, Mechanical wave frequency, 25, 30, 40, 50, and 60 Hz; the spatial resolution: 2 × 2× 2.5 mm3, FOV: 384 x 256; repetition time: 1820 ms; echo time: 54 ms; Matrix: 192 x 128; Perfusion MRI: a 2D fast spoiled gradient echo multi flip-angle T1 map was produced before contrast agent injection with FOV: 60×60×40 mm3; thickness: 2.0 mm; TR:12.4 ms; TE:2.1 ms; matrix: 256 × 128; NEX: 1; with different flip angle 5°, 10°, 20°, 30°, 40°, 50°. The parameters of DCE-MRI were the same as those above, except the flip angle was 30°, after six phase baseline images, 0.025mM/kg Gd of Gd-EOB-DTPA, then 40 phase images were acquired. Liver specificity contrast agents enhanced imaging parameters: 3.0T MR, 12 channels on the surface phased array coil, VIBE: Volume Interpolated Breath-hold Examination, repetition time: 3.1 ms; echo time: 1.16 ms; reconstruction resolution size: 1.3 ×1. 3 × 1.3 mm3; The scanning resolution: 1.7 ×1. 3 ×1. 3 mm3. The MR functions parameters are collected: the liver, the spleen elasticity; 4 D-flow: the superior mesenteric vein (SMV), splenic vein (SV), portal vein (PV) of flow volume, pulse wave velocity (PWV); Perfusion: rCBV, rCBF, MTT; T1 mapping: liver, spleen and kidney T1 values; Magnetic resonance liver cell specificity of contrast agents enhancement: arterial phase, portal phase, liver and gall T1WI signal value of liver tissue. The MR function parameter changes as followed after TIPS will be analyzed. The MR function parameters with chemical biomarkers to predict survival will be analyzed.

Dates

Last Verified: 03/31/2019
First Submitted: 09/25/2018
Estimated Enrollment Submitted: 04/28/2019
First Posted: 04/30/2019
Last Update Submitted: 04/28/2019
Last Update Posted: 04/30/2019
Actual Study Start Date: 08/27/2018
Estimated Primary Completion Date: 08/29/2024
Estimated Study Completion Date: 05/29/2025

Condition or disease

Liver Cirrhosis
Transjugular Intrahepatic Portosystemic Shunt (TIPS)
Functional Magnetic Resonance Imaging

Intervention/treatment

Procedure: Decompensated liver cirrhosis with TIPS

Phase

-

Arm Groups

ArmIntervention/treatment
Decompensated liver cirrhosis with TIPS
Procedure: Decompensated liver cirrhosis with TIPS
TIPS: Established distributary channel between the portal vein and hepatic vein via the jugular vein, portal vein blood directly shunts into the systemic circulation to reduce portal vein pressure to effectively prevent bleeding and refractory ascites.

Eligibility Criteria

Ages Eligible for Study 18 Years To 18 Years
Sexes Eligible for StudyAll
Sampling methodNon-Probability Sample
Accepts Healthy VolunteersYes
Criteria

Inclusion Criteria:

- 18-75 years old;

- Liver cirrhosis (diagnosis by imaging, laboratory examination, clinical symptoms and liver biopsy);

- History of endoscopy confirmed esophageal varicose vein hemorrhage (5 days or higher);

- The Child-Pugh, B or C less 13;

- Willing to participate in this clinical study, and sign an informed consent.

Exclusion Criteria:

- Child-Pugh ≥12 or MELD ≥18;

- Non-cirrhotic portal hypertension (including regional portal hypertension); total bilirubin over 2 times upper;

- Combined liver cancer or other malignant tumor;

- Infection, uncontrolled sepsis, etc.;

- Heart, lung, kidney and other organs, severe disease;

- Women during pregnancy or lactation.

Outcome

Primary Outcome Measures

1. mortality rate [5 years]

2. Incidence of hepatic encephalopathy [5 years]

3. Varices rebleeding rate [5 years]

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge