Acta Ophthalmologica 2016-May

Customized humanoptics silicone iris prosthesis in eyes with posttraumatic iris loss: outcomes and complications.

Only registered users can translate articles
Log In/Sign up
The link is saved to the clipboard
Martin Stephan Spitzer
Anja Nessmann
Julia Wagner
Efdal Yoeruek
Karl Ulrich Bartz-Schmidt
Peter Szurman
Gesine B Szurman

Keywords

Abstract

OBJECTIVE

Posttraumatic partial or total iris defects often cause significant debilitating glare, photophobia, decreased vision and cosmetic problems. Currently, the best cosmetic results can be obtained with a customized silicone iris prosthesis. However, little is known about the functional results and the rate of complication if this type of iris prosthesis is implanted into severely traumatized eyes. The aim of this study is to analyse the functional and cosmetic outcomes as well as complications after Artificial Iris implantation.

METHODS

A consecutive series of 34 patients who received a customized silicone iris prosthesis after severe globe injury with total or sub-total iris loss was analysed retrospectively. Additionally, patients were interviewed regarding change in subjective complaints.

RESULTS

Median follow-up was 24 months (range 12.0-48.8). Mean visual acuity prior to Artificial Iris implantation was 1.1 logMAR (range 0.3-2.6). Five patients (15%) had pre-existing glaucoma and eight patients (24%) had pre-existing hypotony. Visual acuity 12 months after surgery was 1.4 logMAR (range 0.2-2.6). Complications included newly diagnosed glaucoma in three eyes (9%) and hypotony in three eyes (9%), persisting intraocular inflammation or macular oedema in seven patients (21%), and corneal endothelial decompensation requiring corneal transplantation in six patients (18%). Patients' satisfaction increased by reducing glare and enhanced cosmetic appearance.

CONCLUSIONS

The customized silicone iris prosthesis is an individualized treatment approach with appealing cosmetic results. Therefore, especially traumatized eyes with highly different posttraumatic conditions could benefit. However, in some patients, the implantation of this device may cause an increase of intraocular pressure, corneal endothelial decompensation or persisting inflammation.

Join our facebook page

The most complete medicinal herbs database backed by science

  • Works in 55 languages
  • Herbal cures backed by science
  • Herbs recognition by image
  • Interactive GPS map - tag herbs on location (coming soon)
  • Read scientific publications related to your search
  • Search medicinal herbs by their effects
  • Organize your interests and stay up do date with the news research, clinical trials and patents

Type a symptom or a disease and read about herbs that might help, type a herb and see diseases and symptoms it is used against.
*All information is based on published scientific research

Google Play badgeApp Store badge