Oxygen Saturation Alarms in the Neonatal Intensive Care Unit

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
EstadoTerminado
Patrocinadores
Medtronic - MITG

Palabras clave

Abstracto

Infants will be observed in the neonatal intensive care unit for 4 hours. The observer will note the timing of oxygen saturation alarms, staff response, and interrupted staff activities.

Descripción

False alarms may be particularly prevalent in the neonatal intensive care unit (NICU) where uncontrolled motion of infants can intensify the problem. The performance of pulse oximeters is of particular importance in the NICU because of the danger that both hyperoxemia and hypoxemia pose to newborns; hyperoxemia can lead to chronic lung disease or retinopathy of prematurity, and hypoxemia depresses spontaneous ventilation. High false alarm rates contribute to the problem of noise in the NICU. They also have the potential to endanger patients if clinicians become inured to the continual alarms and ignore some that may be clinically relevant. There have been few studies on the utility of pulse oximeter alarms in the NICU, particularly with the new-generation technology. This study will build on the small body of existing literature on alarm rates in new-generation pulse oximeters in neonates and provide details about the relationship of the alarms to clinical interventions.

This is an observational study of 50 infants at three hospitals in the United States. The observer will be an experienced nurse with comprehensive training to ensure consistency. The infants and clinical staff will be observed for four hours continuously. Observers will note the timing of alarms, response, interrupted clinical staff activities, and any clinical interventions, and timing of interventions. Clinical staff will also be questioned on whether the alarm was consistent with a desaturation event. Infant characteristics may affect the frequency of alarms. Data collected will include age, gender, weight, ethnicity, diagnosis, and medications.

This study will evaluate the proportion of nuisance alarms relative to the proportion of clinically relevant alarms. It will also evaluate the differences in alarm frequencies across infant characteristics and characterize nurse activities interrupted by the alarms.

fechas

Verificado por última vez: 07/31/2014
Primero enviado: 03/09/2010
Inscripción estimada enviada: 03/10/2010
Publicado por primera vez: 03/11/2010
Última actualización enviada: 08/04/2014
Última actualización publicada: 08/06/2014
Fecha de los primeros resultados enviados: 05/01/2012
Fecha de los primeros resultados de CC enviados: 07/30/2012
Fecha de los primeros resultados publicados: 09/04/2012
Fecha de inicio real del estudio: 12/31/2009
Fecha estimada de finalización primaria: 03/31/2010
Fecha estimada de finalización del estudio: 05/31/2010

Condición o enfermedad

Hypoxemia

Fase

-

Criterio de elegibilidad

Sexos elegibles para estudiarAll
Método de muestreoNon-Probability Sample
Acepta voluntarios saludablessi
Criterios

Inclusion Criteria:

- Infants in the NICU continuously monitored by pulse oximetry

Exclusion Criteria:

- Infants whose legal guardians do not consent

Salir

Medidas de resultado primarias

1. Detection of Oxygen Alarms That Resulted in Clinicians Changing the Care of the Infant. [4 hours]

Sat Secs is an oxygen alarm with 5 settings:0,10,25,50,and 100. At each setting,using the units of seconds,it filters nusiance alarms & identifies important alarms that result in the clinicians changing the care of the infant.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge