Immunoturbidimetric determination of lipoprotein(a): improvement in the measurement of turbid and triglyceride-rich samples.

Solo los usuarios registrados pueden traducir artículos
Iniciar sesión Registrarse
El enlace se guarda en el portapapeles.
E A Molinari
P F Pichler
H Grillhofer
G M Kostner

Palabras clave

Abstracto

Immunoturbidimetry (IT), a widely used method in clinical chemical laboratories, was checked for its suitability for lipoprotein(a) (Lp(a)) quantification. When the conventional sample diluents were used, turbidimetry gave false results particularly with frozen or lipemic sera which correlated poorly with electroimmunodiffusion (EID). L-Proline which is known to dissociate Lp(a) from other apo B-containing lipoproteins improved the results considerably. One hundred frozen sera were investigated in IT with and without the addition of L-proline to the sample diluent. EID served as a comparison method. In a method comparison (IT vs. EID) linear regression analysis improved from r = 0.793: y = 0.89x - 9.4 (without L-proline) to r = 0.949: y = 0.98x + 4.8 (with L-proline). The improvement of the correlation of the two methods was most pronounced in sera with triglyceride values exceeding 5.5 mmol/l. The IT assay described here was linear between 50 and 1100 mg/l. Total imprecision (coefficient of variation) was below 10%. The assay was not affected by the addition of LDL or plasminogen to the samples. The Lp(a) concentration of the calibrator, i.e. a secondary standard serum, was compared with that of a purified primary Lp(a) standard which consisted of a mixture of four apo(a) isoforms. Total Lp(a) mass (lipids, protein, carbohydrates) was determined chemically and was compared with the Lp(a) mass determined immunochemically by IT and EID. Recovery of the purified Lp(a) was 106% (range 90-116%) in IT and 102% (range 91-115%) in EID. Dose response curves from pure single isoforms (S1 and S4), calibrator and serum samples were parallel. We consider IT to be a simple and rapid method for Lp(a) quantification which is not biased by different apo(a) isoforms.

Únete a nuestra
página de facebook

La base de datos de hierbas medicinales más completa respaldada por la ciencia

  • Funciona en 55 idiomas
  • Curas a base de hierbas respaldadas por la ciencia
  • Reconocimiento de hierbas por imagen
  • Mapa GPS interactivo: etiquete hierbas en la ubicación (próximamente)
  • Leer publicaciones científicas relacionadas con su búsqueda
  • Buscar hierbas medicinales por sus efectos.
  • Organice sus intereses y manténgase al día con las noticias de investigación, ensayos clínicos y patentes.

Escriba un síntoma o una enfermedad y lea acerca de las hierbas que podrían ayudar, escriba una hierba y vea las enfermedades y los síntomas contra los que se usa.
* Toda la información se basa en investigaciones científicas publicadas.

Google Play badgeApp Store badge