Estonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
New England Journal of Medicine 2015-11

Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
Raj R Makkar
Gregory Fontana
Hasan Jilaihawi
Tarun Chakravarty
Klaus F Kofoed
Ole De Backer
Federico M Asch
Carlos E Ruiz
Niels T Olsen
Alfredo Trento

Märksõnad

Abstraktne

A finding of reduced aortic-valve leaflet motion was noted on computed tomography (CT) in a patient who had a stroke after transcatheter aortic-valve replacement (TAVR) during an ongoing clinical trial. This finding raised a concern about possible subclinical leaflet thrombosis and prompted further investigation.

We analyzed data obtained from 55 patients in a clinical trial of TAVR and from two single-center registries that included 132 patients who were undergoing either TAVR or surgical aortic-valve bioprosthesis implantation. We obtained four-dimensional, volume-rendered CT scans along with data on anticoagulation and clinical outcomes (including strokes and transient ischemic attacks [TIAs]).

Reduced leaflet motion was noted on CT in 22 of 55 patients (40%) in the clinical trial and in 17 of 132 patients (13%) in the two registries. Reduced leaflet motion was detected among patients with multiple bioprosthesis types, including transcatheter and surgical bioprostheses. Therapeutic anticoagulation with warfarin, as compared with dual antiplatelet therapy, was associated with a decreased incidence of reduced leaflet motion (0% and 55%, respectively, P=0.01 in the clinical trial; and 0% and 29%, respectively, P=0.04 in the pooled registries). In patients who were reevaluated with follow-up CT, restoration of leaflet motion was noted in all 11 patients who were receiving anticoagulation and in 1 of 10 patients who were not receiving anticoagulation (P<0.001). There was no significant difference in the incidence of stroke or TIA between patients with reduced leaflet motion and those with normal leaflet motion in the clinical trial (2 of 22 patients and 0 of 33 patients, respectively; P=0.16), although in the pooled registries, a significant difference was detected (3 of 17 patients and 1 of 115 patients, respectively; P=0.007).

Reduced aortic-valve leaflet motion was shown in patients with bioprosthetic aortic valves. The condition resolved with therapeutic anticoagulation. The effect of this finding on clinical outcomes including stroke needs further investigation. (Funded by St. Jude Medical and Cedars-Sinai Heart Institute; Portico-IDE ClinicalTrials.gov number, NCT02000115; SAVORY registry, NCT02426307; and RESOLVE registry, NCT02318342.).

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge