Estonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
International Journal of Artificial Organs 1999-Sep

Trillium coating of cardiopulmonary bypass circuits improves biocompatibility.

Ainult registreeritud kasutajad saavad artikleid tõlkida
Logi sisse
Link salvestatakse lõikelauale
H T Tevaearai
X M Mueller
I Seigneul
M Burki
J Horisberger
F Stumpe
L K Von Segesser

Märksõnad

Abstraktne

Coating of cardiopulmonary bypass circuits may be a solution to prevent adverse effects induced by contact of blood elements with foreign surfaces. Using an animal model, we investigated the Trillium TM coating of cardiopulmonary bypass circuits (a new process involving polyethylene oxide, sulphonate groups and heparin) at low systemic heparinization, focusing on haemolysis and clot formation. Cardiopulmonary bypass was initiated through jugulo-carotid access with ACT maintained around 180 sec. Treated circuits (Trillium group) were evaluated in 3 calves (mean weight of 66.0+/-8.7 kg), vs. untreated circuits in 3 control calves (mean weight of 60.7+/-7.5 kg). Blood samples were drawn at regular intervals for biochemical, hematological and blood gas analyses. After 6 consecutive hours, the animals were weaned from CPB and were awakened. The circuits were analyzed for clot deposits. After 7 days the animals were sacrificed and an autopsy was carried out. Red cell and white cell counts did not change over the 6 hours. Platelet counts dropped to 75.9+/-7.3% of the baseline value in the Trillium group after 6 hours whereas counts dropped to 57.2+/-26.0 in the control group (p<0.05). Plasma free Hb remained constant in the Trillium group but increased significantly to 280+/-65% of baseline value in the control group (p<0.05). The amount of clots were significantly higher in the control group, in the connectors, the reservoir, the heat exchanger, and the oxygenator. No renal emboli were seen in the Trillium group whereas the mean number of emboli was 3.0+/-2.4 in the control group. We conclude that Trillium coating significantly improves the biocompatibility of artificial surfaces exposed to blood.

Liitu meie
facebooki lehega

Kõige täiuslikum ravimtaimede andmebaas, mida toetab teadus

  • Töötab 55 keeles
  • Taimsed ravimid, mida toetab teadus
  • Maitsetaimede äratundmine pildi järgi
  • Interaktiivne GPS-kaart - märgistage ürdid asukohas (varsti)
  • Lugege oma otsinguga seotud teaduspublikatsioone
  • Otsige ravimtaimi nende mõju järgi
  • Korraldage oma huvisid ja hoidke end kursis uudisteuuringute, kliiniliste uuringute ja patentidega

Sisestage sümptom või haigus ja lugege ravimtaimede kohta, mis võivad aidata, tippige ürdi ja vaadake haigusi ja sümptomeid, mille vastu seda kasutatakse.
* Kogu teave põhineb avaldatud teaduslikel uuringutel

Google Play badgeApp Store badge