Français
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Obstetrics and Gynecology 1994-May

The endometrial ablator: a new instrument.

Seuls les utilisateurs enregistrés peuvent traduire des articles
Se connecter S'inscrire
Le lien est enregistré dans le presse-papiers
R S Neuwirth
A A Duran
A Singer
R MacDonald
L Bolduc

Mots clés

Abstrait

A thermal balloon and control system designed to produce endometrial ablation blindly is described. A latex balloon on a plastic catheter is inserted into the uterus and connected to a control unit. The unit monitors the pressure and temperature of 5% dextrose in water, which has been injected into the balloon to make it conform to the size and shape of the endometrial cavity. The balloon contains a shielded heating element that is activated to heat the liquid in the balloon to a temperature of 92C. The pressure control deactivates the heating element if the pressure falls below 45 mmHg or rises above 165 mmHg. A timer controls and measures the elapsed interval of heating. The device was tested in human uterine specimens for the potential for uterine perforation, uterine rupture, and thermal effects. Subsequently, the device was tested in six patients in Mexico and four patients in London during hysterectomy just after the abdomen was opened. Thermistor probes were placed at various loci in the uterus to monitor temperature during activation of the thermal balloon. Serosal temperatures were unchanged and endometrial temperatures rose to about 90C. The extent of uterine tissue damage was determined in Mexico City by the zone of visible coagulation of the cut wall of the uterus following removal. In London, tissue diaphorase was measured to determine the depth of destruction of the cellular oxidative enzymes. These measurements varied from 3.3-10 mm under the conditions of time and temperature used. The safety features and the potential for clinical application are discussed.

Rejoignez notre
page facebook

La base de données d'herbes médicinales la plus complète soutenue par la science

  • Fonctionne en 55 langues
  • Cures à base de plantes soutenues par la science
  • Reconnaissance des herbes par image
  • Carte GPS interactive - étiquetez les herbes sur place (à venir)
  • Lisez les publications scientifiques liées à votre recherche
  • Rechercher les herbes médicinales par leurs effets
  • Organisez vos intérêts et restez à jour avec les nouvelles recherches, essais cliniques et brevets

Tapez un symptôme ou une maladie et lisez des informations sur les herbes qui pourraient aider, tapez une herbe et voyez les maladies et symptômes contre lesquels elle est utilisée.
* Toutes les informations sont basées sur des recherches scientifiques publiées

Google Play badgeApp Store badge