Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Lung 1988

Humidifier lung and humidifier fever.

Samo registrirani korisnici mogu prevoditi članke
Prijava Registriraj se
Veza se sprema u međuspremnik
X Baur
J Behr
M Dewair
W Ehret
G Fruhmann
C Vogelmeier
W Weiss
V Zinkernagel

Ključne riječi

Sažetak

The aim of our study was to evaluate clinical diagnoses in symptomatic persons exposed to aerosols from humidifiers or air conditioners. In addition, we tried to identify the causative antigens. Results of clinical investigations, including inhalation challenge tests, demonstrated a typical hypersensitivity pneumonitis (humidifier lung) in 9 persons and isolated systemic symptoms without significant changes in lung function and chest x-rays (humidifier fever) in 3 persons. Microbiological studies revealed a variety of fungi and bacteria in the water supplies of humidifiers and air conditioners at patients' workplaces. The detection of 4 members of the order Sphaeropsidales (Deuteromycotina), not previously associated with humidifier-induced diseases, is of special interest. By means of an improved polystyrene tube-immunoradiometric assay, high concentrations of IgG antibodies against extracts prepared from water of patients' humidifier systems were found in all cases. In addition, patients demonstrated low concentrations of IgG antibodies against thermophilic Actinomycetes, and usually also against various fungi, such as Alternaria tenuis, Aureobasidium pullulans, Penicillium notatum, Aspergilli, and fungi of the order Sphaeropsidales, which were isolated and cultured from humidifier water supplies. The much higher concentrations of antibodies against humidifier/air conditioner water extracts seem to result from sensitization to a variety of antigens from different fungi and bacteria. For in vivo and in vitro diagnostic tests in humidifier-induced lung diseases, we especially recommend using extracts from water systems installed at the corresponding workplaces.

Pridružite se našoj
facebook stranici

Najkompletnija baza ljekovitog bilja potpomognuta znanošću

  • Radi na 55 jezika
  • Biljni lijekovi potpomognuti znanošću
  • Prepoznavanje bilja slikom
  • Interaktivna GPS karta - označite bilje na mjestu (uskoro)
  • Pročitajte znanstvene publikacije povezane s vašom pretragom
  • Pretražite ljekovito bilje po učincima
  • Organizirajte svoje interese i budite u toku s istraživanjem vijesti, kliničkim ispitivanjima i patentima

Upišite simptom ili bolest i pročitajte o biljkama koje bi mogle pomoći, unesite travu i pogledajte bolesti i simptome protiv kojih se koristi.
* Svi podaci temelje se na objavljenim znanstvenim istraživanjima

Google Play badgeApp Store badge