Haitian Creole
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Burn Care and Research

Hydrogen sulfide suicide: a new trend and threat to healthcare providers.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Lyen an sove nan clipboard la
John B Ruder
Jeanette G Ward
Scott Taylor
Karon Giles
Thomas Higgins
James M Haan

Mo kle

Abstrè

First popularized in Japan, hydrogen sulfide (H2S) gas suicide is an underreported form of suicide with known risk for secondary disaster. Mortality rate commonly exceeds 90% because of the gas's lethal, noncontained nature. Instances in the United States are increasing, up from 2 cases in 2008 to 18 in 2010. Because H2S poisonings remain rare, there exists a lack of knowledge regarding the residual effects of gas venting after victim extrication. Identifying instances of the efficacious use of personal protection equipment (PPE) is critical in the effort to alleviate risks faced by hospital and rescue personnel. The current case demonstrates the effective use of PPEs after prolonged H2S exposure. In 2011, a 20-year-old man threatened suicide using H2S gas inside a vehicle on a remote rural highway. First responders identified a "rotten egg smell" and subsequently experienced low poisoning symptoms. After prolonged Hazmat-assisted extrication (4 hours) the patient was unconscious and experiencing seizures. He was decontaminated on-scene (20 minutes) and transported to the closest hospital (22 minutes). Ambulance personnel who wore PPE and used the ambulance's reverse ventilation system (RVS)reported no adverse effects. The patient was transferred to the authors' burn facility by helicopter (38 minutes). Life-flight personnel, who did not wear PPE (no ventilatory system available), complained of watery eyes, headache, and dizziness. Hospital personnel, who did not use PPE (or RVS), complained of watery eyes or headache. Exposed personnel demonstrated no deficits or residual effects. In spite of spontaneous movement, the patient began to seize and died. This case is unique given the multiple primary and secondary H2S gas exposures involved. Exposed personnel without RVS and not using PPE demonstrated moderate H2S symptoms. PPE (self-contained breathing apparatuses) and RVS were shown to be effective during an H2S emergency; however, there are currently limited data supporting their appropriate use. Until data demonstrating duration of H2S venting for small enclosed spaces are made available, PPEs should be required.

Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge