Journal of the Louisiana State Medical Society : official organ of the Louisiana State Medical Society, The

The Mysterious Case of Dyspnea.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Lyen an sove nan clipboard la
S Saad
N Turaga
J Grant
N Jain

Mo kle

Abstrè

BACKGROUND

Dehiscence of a mitral valve annuloplasty ring is a rare occurrence that often manifests as mitral regurgitation and heart failure. We present a case of mitral ring dehiscence which was initially unrecognized by standard 2-dimensional transthoracic echocardiography (2D TTE); and 2-dimensional transesophageal echocardiography (2D TEE);.

METHODS

A 65-year-old woman was referred to Cardiology clinic for evaluation of dyspnea. Her history included tobacco abuse, atrial fibrillation status post pulmonary vein isolation, nonischemic cardiomyopathy, and prior mitral valve repair with annuloplasty ring for rheumatic valvular disease. She had been asymptomatic post-surgery. Physical examination, cardiac rhythm and initial ischemic workup were unremarkable. Pulmonary function tests revealed moderate emphysematous type obstructive lung disease. A 2D TTE demonstrated moderate mitral regurgitation with normal left ventricular function. In right heart catheterization, large v waves were noted and 2D TEE also revealed severe mitral regurgitation. On 2D TEE, the mitral valve annuloplasty ring was visible above the native anterior mitral valve leaflet. Color Doppler flow estimated the effective regurgitation orifice area of 0.4cm2 using the proximal isovelocity surface area method and regurgitant volume of 58 cc, consistent with severe mitral regurgitation. A "floating mitral ring" and dehiscence measuring 1 cm in diameter were seen on high resolution three-dimensional reconstruction resulting from the detachment of the ring from the weakened posterior annulus. Based on these findings patient was referred to cardiothoracic surgeon for re-do mitral valve surgery.

CONCLUSIONS

This was a perplexing case as the patient's dyspnea could be explained by many disease processes including atrial fibrillation, mitral regurgitation and chronic obstructive lung disease. The standard imaging modalities did not help us to formulate a diagnosis. 3D TEE provided invaluable and unparalleled information of mitral valve pathology. Annuloplasty ring dehiscence is a well described complication of mitral valve repair and should always be considered in symptomatic patients.

Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge