Haitian Creole
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

refractive errors/hypoxia

Lyen an sove nan clipboard la
Paj 1 soti nan 25 rezilta yo
BACKGROUND A small but significant increase in myopia after extended wear of low oxygen permeability (Dk) hydrogel lenses has been previously reported; however, the specific impact of hypoxia on refractive status and corneal curvature with extended wear are not well documented. THE PURPOSE of this
BACKGROUND A small but significant increase in myopia after extended wear of low oxygen permeability (Dk) hydrogel lenses has been previously reported; however, the specific impact of hypoxia on refractive status and corneal curvature with extended wear are not well documented. The purpose of this

Clinical signs of hypoxia with high-Dk soft lens extended wear: is the cornea convinced?

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE To assess the effectiveness of high-Dk soft contact lenses with oxygen transmissibility (Dk/L) beyond the critical level required to avoid corneal edema during overnight wear. METHODS The most up-to-date data available on clinical signs of hypoxia with high-Dk contact lenses is

Have silicone hydrogel lenses eliminated hypoxia?

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE The purpose of this article is to review the literature to date to determine if silicone hydrogel lenses have eliminated corneal hypoxia. METHODS Results from clinical studies, including short-term laboratory studies and retrospective and prospective clinical trials that have assessed the

Acute hypoxia influences collagen and matrix metalloproteinase expression by human keratoconus cells in vitro.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Keratoconus (KC) is a progressive corneal ectasia linked to thinning of the central cornea. Hard contact lenses, rigid gas permeable lenses, and scleral lenses are the primary treatment modalities for early to mid- stages of KC to correct refractive error and astigmatism that develops as a result of

Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
To evaluate the relationships between refractive error, axial length (AL), and retinal vascular oxygen saturation in an adult population.This was a hospital-based, prospective observational study. The left eyes of phakic adult subjects without media opacity

Corneal oxygen deficiency.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE To compare the ocular effects of low Dk hydrogel and high Dk silicone hydrogel contact lenses. METHODS A review of recent literature was conducted to determine the effects of wearing low and high Dk soft lenses on corneal swelling, vascular response, refractive error and the corneal
BACKGROUND Central corneal thickness (CCT) is an important indicator of corneal status. Its measurement provides valid information about corneal physiological condition and possible changes associated with diseases, traumas, and hypoxia. It is an integral part for interpretation of intraocular

The Berkeley Contact Lens Extended Wear Study. Part II : Clinical results.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE To describe the principal clinical outcomes associated with 12 months use of rigid gas-permeable (RGP) extended wear contact lenses and address two primary study questions: (1) does extended wear (EW) of high oxygen transmissibility (Dk/t) RGP lenses reduce the incidence of ocular

Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE Silicone hydrogel (SiH) lenses offer many physiological advantages for daily wear (DW) in addition to the continuous-wear modality for which they were originally developed. The purpose of this study was to investigate the clinical performance and physiological responses in a group of

The Berkeley Contact Lens Extended Wear Study. Part I : Study design and conduct.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
OBJECTIVE The primary aim of the Berkeley Contact Lens Extended Wear Study (CLEWS) was to test the hypotheses that extended wear of rigid gas-permeable (RGP) contact lenses with greater oxygen permeability (Dk) reduces the incidence of contact lens-associated keratopathy (CLAK) and increases the

Specular microscopy of hard contact lens wearers.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Wide-field specular microscopy, slit-lamp examination, and pachometry were performed on 22 successful hard contact lens wearers and 22 controls matched for age, race, sex, and refractive error. A minimum of 600 cells per control and 1200 per contact lens wearer were manually digitized from the

The use of contact lenses by USAF aviators.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Contact lenses are an alternative method to spectacles for correcting refractive errors, but the U.S. Air Force prohibits the wearing of contact lenses by all aircrew members unless medically or optically indicated (AFR 167-3). USAFSAM has a clinical contact lens study consisting of 55 individuals

Stability of laser-assisted in situ keratomileusis (LASIK) at altitude.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
BACKGROUND The U.S. Air Force approved laser-assisted in situ keratomileusis (LASIK) for aircrew in May 2007. Relative to photorefractive keratectomy (PRK), LASIK potentially offers a more rapid return to flight status; however, there are concerns regarding corneal stability at altitude after
OBJECTIVE Retinopathy of prematurity (RoP) is a retinal vascular disease and a frequent cause of blindness in infants. Our objective was to measure the frequency of RoP in infants with extremely low birth weight (ELBW, < 1,000 g) at the National Institute of Perinatology, Neonatal Intensive Care
Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge