CRE8 in All Comers Patients

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
状態完了
スポンサー
Tel-Aviv Sourasky Medical Center

キーワード

概要

The purpose of the study is to evaluate clinical performances of Cre8 in all comer population in Subjects over 18 years old who are undergoing a clinically indicated coronary angiogram and angioplasty on de-novo lesion located in native coronary arteries

説明

The development, clinical validation, and widespread use of drug-eluting stents have revolutionized the treatment of patients with coronary artery disease. Large scale, prospective, multicenter double-blind randomized trials have provided strong evidence that sirolimus-eluting stents, paclitaxel-eluting stents, and zotarolimus-eluting stents significantly reduce angiographic restenosis and enhance event-free survival compared with bare-metal stents after implantation in native coronary arteries1. However, higher rates of late and very late stent thrombosis with SES and PES, likely due to delayed and incomplete endothelialization compared with BMS, have raised safety concerns with DES as a class. Therefore, alongside clinical investigations, histopathological evaluations were conducted on the coronary arteries of patients who died after DES implantation to examine the healing status of the vessel. The evidence obtained suggested that the polymer components used to carry the drug in the first generation of DES may be associated with a local inflammatory response, associated with localized hypersensitivity and eosinophil infiltration, with consequent alteration of the vessel wall and delay in the formation of the endothelium. Because specific stent design and/or polymer features may impact DES performance, numerous studies have focused on the comparative assessment of various DES, with conflicting results.

The clinical need thus exists for enhanced stent designs which offer improved safety and efficacy profiles compared to the earlier stent platforms.

new technologies have been developed which have led to the creation of devices with delivery systems based on the use of more biocompatible or bioabsorbable polymers and cytostatic drugs similar to sirolimus. The clinical data obtained with this second generation have demonstrated, in all devices tested, no less efficacy than first-generation DES, and a better safety profile, although not statistically significant.Concerning the most widely used second generation DES,after a small first-in-man trial, its safety and efficacy was further studied in larger randomized trials on patients with non-complex lesions in which EES was compared to PES, proving its angiographic superiority and clinical non-inferiority. A step forward, in assessing the clinically significant differences among different DES, was done with a new randomized trial comparing EES versus PES, powered for testing superiority in clinical outcomes and of sufficient magnitude to provide data on patient subgroups, particularly patients with diabetes. At present, a third-generation of DES, developed to minimize the possible side effects related to the presence of the polymer, is being evaluated in humans. To avoid the presence of the polymer on the surface of the device, different platforms are being evaluated: those with a porous surface onto which the pure drug is placed and those with holes closed towards the intraluminal part by a bioabsorbable polymer, onto which the drug is loaded. A third option to avoid the need of polymers has been used in the new CRE8 DES, featuring a polymer free platform with abluminal reservoirs to release the Amphilimus formulation. This device has been tested against Taxus Liberté in a randomized clinical trial, to assess the non-inferiority angiographic efficacy results. The 6month angiographic analysis, demonstrates that the primary study endpoint has been achieved, showing that CRE8 was not inferior to Taxus Liberté in terms of efficacy performances.

日付

最終確認済み: 05/31/2016
最初に提出された: 09/12/2012
提出された推定登録数: 09/12/2012
最初の投稿: 09/17/2012
最終更新が送信されました: 06/26/2016
最終更新日: 06/27/2016
実際の研究開始日: 09/30/2012
一次完了予定日: 06/30/2014
研究完了予定日: 07/31/2014

状態または病気

Consecutive Subjects Who Are Suitable for a Coronary
Angioplasty of de Novo Lesion(s) in Native Coronary
Arteries Should be Screened for Eligibility.
A Total Number of 200 Patients Fulfilling the Selection
Criteria and Willing to Sign the Informed Consent Should
be Enrolled in the Trial.

介入/治療

Device: CR8

段階

-

アームグループ

介入/治療
Experimental: CR8
a drug eluting coronary device, made of Cobalt-Chromium alloy and integrally coated with i-Carbofilm™, loaded with formulated Sirolimus
Device: CR8
a drug eluting coronary device, made of Cobalt-Chromium alloy and integrally coated with i-Carbofilm™, loaded with formulated Sirolimus

適格基準

研究の対象となる年齢 18 Years に 18 Years
研究に適格な性別All
健康なボランティアを受け入れるはい
基準

Inclusion Criteria:

- Age over 18 years

- Patients with symptoms of stable angina or documented silent ischemia

- Patient with coronary artery disease ranging between 0 and 22 according to the Syntax score

- Patients with acute coronary syndrome, including unstable angina, NSTEMI and STEMI

- Patient is eligible for percutaneous coronary intervention and is an acceptable candidate for surgical revascularization

- Left ventricular ejection fraction > 30%;

- Target de-novo lesions with diameter stenosis > 50% (including total occlusion)

- Target lesion located in a target vessel with a diameter ranging from 2.5 to 4.0 mm;

- patient has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Ethical Committee of the respective clinical site.

Exclusion Criteria:

- Female with childbearing potential or lactating;

- Known allergies to antiplatelets, anticoagulants, contrast media, sirolimus or cobalt chromium;

- Acute or chronic renal dysfunction (defined as creatinine greater than 2.5 mg/dl or on dialysis);

- Thrombocytopenia (platelet count less than 100,000/mm³) or hypercoagulable disorder;

- Known significant gastro-intestinal or urinary bleeding within the past 6 months;

- Patient refusing blood transfusion;

- Patient currently under immunosuppressant therapy;

- Patient with planned surgery within 6 months from the index procedure unless dual antiplatelet therapy is maintained throughout the peri-surgical period;

- Co-morbidities that could interfere with completion of study procedures, or life expectancy less than 1 year;

- Participating in another investigational drug or device trial that has not completed the primary endpoint or would interfere with the endpoints of this study;

- Patient underwent target vessel revascularization, with a DES, within 3 months prior to the index procedure;

- Target lesion is located or supplied by an arterial or venous bypass graft

結果

主な結果の測定

1. Incidence of 6-month device-oriented clinical composite endpoint, defined as Cardiac death / Target vessel MI / Clinically indicated TLR [6 months]

二次的な結果の測定

1. Incidence of clinical composite endpoints at 30 days, 1 year from the index procedure [1 year]

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge