Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
International Journal of Artificial Organs 1999-Sep

Trillium coating of cardiopulmonary bypass circuits improves biocompatibility.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
H T Tevaearai
X M Mueller
I Seigneul
M Burki
J Horisberger
F Stumpe
L K Von Segesser

キーワード

概要

Coating of cardiopulmonary bypass circuits may be a solution to prevent adverse effects induced by contact of blood elements with foreign surfaces. Using an animal model, we investigated the Trillium TM coating of cardiopulmonary bypass circuits (a new process involving polyethylene oxide, sulphonate groups and heparin) at low systemic heparinization, focusing on haemolysis and clot formation. Cardiopulmonary bypass was initiated through jugulo-carotid access with ACT maintained around 180 sec. Treated circuits (Trillium group) were evaluated in 3 calves (mean weight of 66.0+/-8.7 kg), vs. untreated circuits in 3 control calves (mean weight of 60.7+/-7.5 kg). Blood samples were drawn at regular intervals for biochemical, hematological and blood gas analyses. After 6 consecutive hours, the animals were weaned from CPB and were awakened. The circuits were analyzed for clot deposits. After 7 days the animals were sacrificed and an autopsy was carried out. Red cell and white cell counts did not change over the 6 hours. Platelet counts dropped to 75.9+/-7.3% of the baseline value in the Trillium group after 6 hours whereas counts dropped to 57.2+/-26.0 in the control group (p<0.05). Plasma free Hb remained constant in the Trillium group but increased significantly to 280+/-65% of baseline value in the control group (p<0.05). The amount of clots were significantly higher in the control group, in the connectors, the reservoir, the heat exchanger, and the oxygenator. No renal emboli were seen in the Trillium group whereas the mean number of emboli was 3.0+/-2.4 in the control group. We conclude that Trillium coating significantly improves the biocompatibility of artificial surfaces exposed to blood.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge