Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

tantalum/infarction

リンクがクリップボードに保存されます
記事臨床試験特許
ページ 1 から 17 結果
[13N]Ammonia is commonly produced using 16O(p, α)13N reaction but one of the limiting factor of this reaction is the relatively small nuclear cross-section at proton energies of <10 MeV. An alternative production method using 13C(p, n)13N

Angiographic follow-up and clinical experience with the flexible Tantalum Cordis stent.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
The Cordis stent is a flexible, highly radioopaque intracoronary stent engineered from a single Tantalum filament folded into a sinusoidal helical coil. It is premounted on a semicompliant balloon expandable stent delivery system. From September 1995-March 1996, 147 Cordis stents were deployed in

Multicenter evaluation of the Strecker tantalum stent for acute coronary occlusion after angioplasty.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
The Strecker stent is a balloon-expandable, flexible endoprosthesis constructed of knitted tantalum wire and has been implanted successfully in peripheral arteries. This study presents the first multicenter experience with implantation of this radiopaque device in the coronary arteries in 64

Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
BACKGROUND The use of genetically altered mice as a model system to study cardiovascular disease has created a need for accurate and quantitative assessment of murine ventricular function. To address this very challenging problem, we have developed a technique of murine first-pass radionuclide

Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multicenter clinical study.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
OBJECTIVE The objective of this study was to assess the safety and efficacy of 2 novel cervical interbody fusion devices in the treatment of single-level degenerative cervical disk disease. Both devices were fabricated from a porous tantalum material. The high overall porosity of the devices was

Intracoronary Stents

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
September 16, 1977, in Zurich Germany, Andreas Grunzig performed the first balloon angioplasty in a coronary artery on Andreas Bachman. Grunzig used the first known balloon, a DG 20-30. This method of treating a coronary artery was effective 10 to 20 years after Bachman performed this first

Silicon Carbide Coating Ñ A Semiconducting Hybrid Design of Coronary Stents Ñ A Feasibility Study.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
OBJECTIVE: To determine the rates of subacute and acute thrombotic stent occlusion in patients with normal and high risk for stent thrombosis and to assess the 6 month follow-up with respect to in-stent restenosis, using a new principle of semiconductor coating (active passivating as metallic hybrid

Coronary stents.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
As early as 1912, endovascular support devices were tried in canine aortas to maintain luminal patency in various conditions. Stents were introduced into clinical practice in 1986 to treat abrupt closure and to prevent restenosis after angioplasty. In 1994, two major randomised trials have confirmed

Failure of nitroglycerin introduced after prolonged myocardial ischemia to improve collateral blood flow and function in tranquilized dogs.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
This study investigated whether nitroglycerin can improve ischemic zone blood flow and function when its infusion is delayed following left anterior descending (LAD) occlusion. Nitroglycerin (200 micrograms/min, 11 dogs) or saline (six dogs) was infused for 2 hours starting 2 hours after occlusion.

Effects of acute, transient coronary occlusion on global and regional right ventricular function in humans.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
OBJECTIVE The aim of this study was to investigate the changes in right ventricular function during acute coronary occlusion produced by inflating a coronary angioplasty balloon catheter. BACKGROUND Alterations in right ventricular function are well known to occur in patients with acute myocardial
This study was retrospectively designed to examine if the Wiktor stent, a balloon-expandable tantalum coil stent, provides a more favorable procedural and long-term clinical and angiographic outcome than does conventional coronary balloon angioplasty (POBA). From April 1995 to April 1996, we

Clinical experience with the Wiktor stent in native coronary arteries and coronary bypass grafts.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
OBJECTIVE To evaluate the results of implantation of Wiktor tantalum wire coronary stents in stenosed or occluded coronary vessels or in saphenous vein bypass grafts. METHODS A retrospective analysis of clinical and angiographic data from patients treated with tantalum wire stents implanted by one

Long term follow-up of transcatheter embolization with autologous clot, oxycel and gelfoam in domestic swine.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
Transcatheter embolization of the distal gastrosplenic artery as well as the distal right renal artery or one of its bifurcational branches was performed in 9 domestic swine. The animals were embolized with fresh autologous clot, oxycel or gelfoam in groups of 3. The embolic material was opacified
This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease. Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of

Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
OBJECTIVE To report the results of a prospective, nonrandomized, multicenter study of a semiconductor-coated stent in coronary lesions at high risk for stent thrombosis. METHODS A balloon-expandable tantalum stent was coated with silicon carbide to enhance thromboresistance (Tensum). Patients were
Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge