ページ 1 から 17 結果
[13N]Ammonia is commonly produced using 16O(p, α)13N reaction but one of the limiting factor of this reaction is the relatively small nuclear cross-section at proton energies of <10 MeV. An alternative production method using 13C(p, n)13N
The Cordis stent is a flexible, highly radioopaque intracoronary stent engineered from a single Tantalum filament folded into a sinusoidal helical coil. It is premounted on a semicompliant balloon expandable stent delivery system. From September 1995-March 1996, 147 Cordis stents were deployed in
The Strecker stent is a balloon-expandable, flexible endoprosthesis constructed of knitted tantalum wire and has been implanted successfully in peripheral arteries. This study presents the first multicenter experience with implantation of this radiopaque device in the coronary arteries in 64
BACKGROUND
The use of genetically altered mice as a model system to study cardiovascular disease has created a need for accurate and quantitative assessment of murine ventricular function. To address this very challenging problem, we have developed a technique of murine first-pass radionuclide
OBJECTIVE
The objective of this study was to assess the safety and efficacy of 2 novel cervical interbody fusion devices in the treatment of single-level degenerative cervical disk disease. Both devices were fabricated from a porous tantalum material. The high overall porosity of the devices was
September 16, 1977, in Zurich Germany, Andreas Grunzig performed the first balloon angioplasty in a coronary artery on Andreas Bachman. Grunzig used the first known balloon, a DG 20-30. This method of treating a coronary artery was effective 10 to 20 years after Bachman performed this first
OBJECTIVE: To determine the rates of subacute and acute thrombotic stent occlusion in patients with normal and high risk for stent thrombosis and to assess the 6 month follow-up with respect to in-stent restenosis, using a new principle of semiconductor coating (active passivating as metallic hybrid
As early as 1912, endovascular support devices were tried in canine aortas to maintain luminal patency in various conditions. Stents were introduced into clinical practice in 1986 to treat abrupt closure and to prevent restenosis after angioplasty. In 1994, two major randomised trials have confirmed
This study investigated whether nitroglycerin can improve ischemic zone blood flow and function when its infusion is delayed following left anterior descending (LAD) occlusion. Nitroglycerin (200 micrograms/min, 11 dogs) or saline (six dogs) was infused for 2 hours starting 2 hours after occlusion.
OBJECTIVE
The aim of this study was to investigate the changes in right ventricular function during acute coronary occlusion produced by inflating a coronary angioplasty balloon catheter.
BACKGROUND
Alterations in right ventricular function are well known to occur in patients with acute myocardial
This study was retrospectively designed to examine if the Wiktor stent, a balloon-expandable tantalum coil stent, provides a more favorable procedural and long-term clinical and angiographic outcome than does conventional coronary balloon angioplasty (POBA). From April 1995 to April 1996, we
OBJECTIVE
To evaluate the results of implantation of Wiktor tantalum wire coronary stents in stenosed or occluded coronary vessels or in saphenous vein bypass grafts.
METHODS
A retrospective analysis of clinical and angiographic data from patients treated with tantalum wire stents implanted by one
Transcatheter embolization of the distal gastrosplenic artery as well as the distal right renal artery or one of its bifurcational branches was performed in 9 domestic swine. The animals were embolized with fresh autologous clot, oxycel or gelfoam in groups of 3. The embolic material was opacified
This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease.
Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of
OBJECTIVE
To report the results of a prospective, nonrandomized, multicenter study of a semiconductor-coated stent in coronary lesions at high risk for stent thrombosis.
METHODS
A balloon-expandable tantalum stent was coated with silicon carbide to enhance thromboresistance (Tensum). Patients were