Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Perinatology 1995-May

From biochemical to biophysical placental function tests in fetal surveillance.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
B Arabin
V Ragosch
A Mohnhaupt

Raktažodžiai

Santrauka

Radioimmunoassays of human placental lactogen and estriol levels in the maternal plasma, ultrasound biometry of the abdominal diameter (AD), pulsed Doppler measurements of uteroplacental arteries, the common carotid artery (CCA), and the umbilical artery (UA) and fetal heart rate monitoring were simultaneously performed in 219 risk pregnancies from 26 weeks' onward at regular intervals. The prognostic value of all tests to predict small for gestational age infants (SGA) and fetal distress was evaluated simultaneously. Receiver operator characteristic allowed the simultaneous comparison of all methods: The AD was most predictive for early detection of SGA, even more than uteroplacental blood flow. Fetal blood flow redistribution expressed as a ratio of the resistance index of CCA/UA was the most significant test for detection of fetal distress later in pregnancy, even more than antenatal cardiotocography. Considering cutoff levels used in clinical routine, the sensitivity and specificity of the fetal AD in detecting intrauterine growth retardation more than 28 days before birth, were 71 and 81%, respectively. Pulsed Doppler measurements of CCA/UA less than 7 days before the delivery had a sensitivity and specificity of 83 and 90%, respectively. Our results demonstrate the historical change in fetal surveillance within one study group: If accurate routine ultrasound is available, the use of biochemical placental function tests is not justified, a procedure that is already accepted in nearly all perinatal centers. Fetal cerebral versus umbilical blood flow measurements should be applied as a tool to measure fetal blood flow redistribution in small fetuses to predict most precisely the risk for poor outcome and perinatal hypoxia.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge