Reactive oxygen species inhibited by titanium oxide coatings.
Raktažodžiai
Santrauka
Titanium is a successful biomaterial that possesses good biocompatibility. It is covered by a surface layer of titanium dioxide, and this oxide may play a critical role in inhibiting reactive oxygen species, such as peroxynitrite, produced during the inflammatory response. In the present study, titanium dioxide was coated onto silicone substrates by radio-frequency sputtering. Silicone coating with titanium dioxide enhanced the breakdown of peroxynitrite by 79%. At physiologic pH, the peroxynitrite donor 3-morpholinosydnonimine-N-ethylcarbamide (SIN-1) was used to nitrate 4-hydroxyphenylacetic acid (4-HPA) to form 4-hydroxy-3-nitrophenyl acetic acid (NHPA). Titanium dioxide-coated silicone inhibited the nitration of 4-HPA by 61% compared to aluminum oxide-coated silicone and 55% compared to uncoated silicone. J774A.1 mouse macrophages were plated on oxide-coated silicone and polystyrene and stimulated to produce superoxide and interleukin-6. Superoxide production was measured by the chemiluminescent reaction with 2-methyl-6-[p-methoxyphenyl]-3,7-dihydroimidazo[1,2-a]pyrazin-3-one (MCLA). Titanium dioxide-coated silicone exhibited a 55% decrease in superoxide compared to uncoated silicone and a 165% decrease in superoxide compared to uncoated polystyrene. Titanium dioxide-coated silicone inhibited IL-6 production by 77% compared to uncoated silicone. These results show that the anti-inflammatory properties of titanium dioxide can be transferred to the surfaces of silicone substrates.