Lithuanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of the Medical Association of Thailand = Chotmaihet thangphaet 1998-Apr

The potential alveolar hazard of carbon dioxide laser-induced smoke.

Straipsnius versti gali tik registruoti vartotojai
Prisijungti Registracija
Nuoroda įrašoma į mainų sritį
S Kunachak
P Sobhon

Raktažodžiai

Santrauka

Carbon dioxide laser is a continuous wave laser, it is well known for its capacity of tremendous smoke production while contact with tissue. Smoke may cause nausea, vomiting, headache and airway irritation. Smoke particles 0.5-2 micrometers in diameter usually travel down the tracheobronchial tree and lodge in the alveoli posing a health hazard. The objectives of this study were to evaluate possible health hazards of carbon dioxide laser smoke in the operating room environment, by determining the size and density of smoke particles also determine the efficacy of surgical masks as a smoke protectant. Ten fresh specimens of papillomatous tissue obtained from the patients were lased by carbon dioxide laser in a continuous mode. The plume generated was collected by 0.45 micrometers pore size microfilter which was attached to the tip of a suction hose connecting the smoke evacuator. The effectiveness of 2 types of commonly used surgical masks were also determined by trapping the smoke after passing through each mask using the same model. Smoke particles were evaluated by scanning electron microscope. The smoke particle density of microfilter that directly trap plume averaged 6 particles/mm2, particles ranging in size from 0.5-27 micrometers, of which 70 per cent were 0.8 micrometers. For the particles trapped after passing through both cotton and paper surgical mask, the size were ranging from 1.6-37 micrometers where 65 per cent were 3.7 micrometers and the particle density average 2.7/mm2. We concluded that the smoke particles derived from carbon dioxide laser application are within the alveolar hazard zone. The conventional surgical masks may not be an effective tool against laser smoke hazard.

Prisijunkite prie mūsų
„Facebook“ puslapio

Išsamiausia vaistinių žolelių duomenų bazė, paremta mokslu

  • Dirba 55 kalbomis
  • Žolelių gydymas, paremtas mokslu
  • Vaistažolių atpažinimas pagal vaizdą
  • Interaktyvus GPS žemėlapis - pažymėkite vaistažoles vietoje (netrukus)
  • Skaitykite mokslines publikacijas, susijusias su jūsų paieška
  • Ieškokite vaistinių žolelių pagal jų poveikį
  • Susitvarkykite savo interesus ir sekite naujienas, klinikinius tyrimus ir patentus

Įveskite simptomą ar ligą ir perskaitykite apie žoleles, kurios gali padėti, įveskite žolę ir pamatykite ligas bei simptomus, nuo kurių ji naudojama.
* Visa informacija pagrįsta paskelbtais moksliniais tyrimais

Google Play badgeApp Store badge