Macedonian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Operative Neurosurgery 2019-Oct

Endoscopic Evacuation of Intracerebral Hematoma Utilizing a Side-Cutting Aspiration Device.

Само регистрираните корисници можат да преведуваат статии
Пријавете се / пријавете се
Врската е зачувана во таблата со исечоци
Jianning Shao
Alex Witek
Hamid Borghei-Razavi
Mark Bain
Pablo Recinos

Клучни зборови

Апстракт

Intracerebral hemorrhage (ICH) is associated with a significant mortality of up to 50%, with almost all survivors suffering from debilitating functional compromise. In most cases, open craniotomy has failed to yield significant survival benefit. However, emerging evidence suggests that minimally invasive surgery (MIS) may yield clinically significant improvements in patient survival and quality of life in cases where open craniotomy has not shown benefit.We report the first documented usage of a side-cutting-aspiration device via an endoscopic approach for the evacuation of a 56cc hematoma, which was a technical modification on previous MIS techniques. The patient is a 50-yr-old female who was transferred emergently to our center with a National Institutes of Health Stroke Scale score of 27 and found to have a large hematoma involving her left basal ganglia. A minimally-invasive approach was elected due to evidence on the risks and suboptimal outcomes of open craniotomy in ICH evacuation. Neuronavigation was used to plan the surgical trajectory for ICH access. Evacuation took place in three main steps: 1) beginning at the center of the clot to remove bulk; 2) mobilizing clots from parenchymal walls to a safe zone via aspiration, followed by clot homogenization; and 3) re-expansion of the cavity via continuous irrigation to allow visualization of further clots. A final inspection was performed to ensure removal of all clots that could be safely removed. The dual functionalities of the device, namely, suction only and suction plus side-cutting functions, enabled key maneuvers, such as clot homogenization and controlled aspiration strength, to be safely performed. A near-total evacuation of the hematoma was achieved without damage to surrounding parenchyma. The patient experienced a rapid clinical course from comatose to discharge-ready in 5 d. At 30-d follow-up, the patient had residual expressive aphasia and was able to ambulate with the assistance of a quad cane. There are no radiographical signs of recurrent hemorrhage or parenchymal injury. Clinical follow-up with this patient is ongoing.This is the first ICH evacuation with a side-cutting-aspiration device via an endoscopic approach. In our patient, this technique proved to be safe and efficacious, suggesting that this technique may be a promising addition to the armamentarium of MIS for ICH evacuation.

Придружете се на нашата
страница на Facebook

Најкомплетната база на податоци за лековити билки поддржана од науката

  • Работи на 55 јазици
  • Лекови од билки поддржани од науката
  • Препознавање на билки по слика
  • Интерактивна GPS мапа - означете ги билките на локацијата (наскоро)
  • Прочитајте научни публикации поврзани со вашето пребарување
  • Пребарувајте лековити билки според нивните ефекти
  • Организирајте ги вашите интереси и останете во тек со истражувањето на новостите, клиничките испитувања и патентите

Напишете симптом или болест и прочитајте за билки што можат да помогнат, напишете билка и видете болести и симптоми против кои се користи.
* Сите информации се базираат на објавени научни истражувања

Google Play badgeApp Store badge