International Endodontic Journal 2019-Jun

Diagnosis of external root resorption in teeth close and distant to zirconium implants: influence of acquisition parameters and artefacts produced during cone beam computed tomography.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
D Freitas
E Nascimento
T Vasconcelos
M Noujeim

Słowa kluczowe

Abstrakcyjny

To assess the influence of artefacts, the metal artefact reduction (MAR) tool and kilovoltage (kVp) on the diagnosis of simulated external root resorption (ERR) in teeth close and distant to zirconium implants in cone beam computed tomography (CBCT) images.Cavities (0.62 mm in diameter and 0.19 mm deep) were created in the apical thirds of 12 roots on the buccal, lingual, distal or mesial surface; ten roots served as controls. The roots were randomly positioned in the first and second right and left premolar sockets of a dry human mandible, and a zirconium implant was placed in the socket of the first right molar. A ProMax 3D unit varying kVp (70, 80, or 90 kVp) and with the MAR tool activated or not was used to obtain CBCT scans. Five examiners evaluated all images to determine the area under the receiver operating characteristic (ROC) curve, sensitivity and specificity.The ROC values and sensitivity were not affected by MAR or artefacts regardless of the distance to the implant (P > 0.05), whilst increasing kVp from 70 to 90 led to a significant increase in these values (P = 0.0202 and 0.0199, respectively). Specificity was not affected by the factors studied (P > 0.05).Amongst the factors studied, only kVp influenced the diagnosis of simulated external root resorption in CBCT images. Increasing kVp from 70 to 90 improved the accuracy in diagnosing the simulated lesions.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge