Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Materials Science: Materials in Medicine 2010-Jan

Evaluation of a novel radiopacifiying agent on the physical properties of surgical spineplex.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
D O'Brien
D Boyd
S Madigan
S Murphy

Słowa kluczowe

Abstrakcyjny

Polymethlylmethacrylate (PMMA) is the most frequently used cement for percutaneous vertebroplasty and kyphoplasty. To aid visualisation during surgery cements are doped with radiopacifying agents such as Barium sulphate (Ba(2)SO(4)) or Zirconium Dioxide (ZiO(2)). Mounting research suggests that these agents may impair the biocompatibility of the cements. However, incorporating an alternative radiopacifier agent with excellent biocompatibility would be a significant step forward. Bioactive radiopaque glasses incorporating elements such as strontium (Sr) and zinc (Zn), known to have beneficial and therapeutic effects on bone, are of great interest in this respect. In this study, the Ba(2)SO(4) of the commercially available Spineplex was incrementally replaced with a radiopaque therapeutic glass composition. The resulting effects on cement setting time, peak isotherm, ultimate compressive strength, Young's modulus (up to 30 days cement maturation) and radiopacity were evaluated. The substitution lead to an increase in cement setting time from 13.1 mins for Spineplex to 16.6-18.3 mins for the glass substituted cements. The peak exotherm during curing was reduced from 74 degrees C for Spineplex to a minimum of 51 degrees C for the fully substituted cement, indicating that reduced thermal necrosis in the in vivo setting is likely with these materials. Ultimate compressive strength and Young's modulus of each formulation showed no significant deterioration due to the substitution. Finally, the radiopacity of the substituted cements were reduced by up to a maximum of 18% in comparison to the control. However, the experimental formulations still maintained radiopacity equivalent to several millimetres of aluminium. As such the substituted cements had substantial equivalence to the Spineplex control. In order to assess the clinical relevance of these findings further investigation is warranted.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge