Journal of Biomedical Materials Research - Part B Applied Biomaterials 2007-Apr

Experimental lumbar spine fusion with novel tantalum-coated carbon fiber implant.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
Haisheng Li
Xuenong Zou
Charlotte Woo
Ming Ding
Martin Lind
Cody Bünger

Słowa kluczowe

Abstrakcyjny

Implants of carbon fiber composite have been widely used in orthopedic and spinal surgeries. However, studies using carbon fiber-reinforced cages demonstrate frequent appearance of fibrous layer interposed between the implant and the surrounding bone. The aim of the present study was to test the possibility of coating a biocompatible metal layer on top of the carbon fiber material, to improve its biological performance. Tantalum was chosen because of its bone compatibility, based on our previous studies. A novel spinal fusion cage was fabricated by applying a thin tantalum coating on the surface of carbon-carbon composite material through chemical vapor deposition. Mechanical and biological performance was tested in vitro and in vivo. Compress strength was found to be 4.9 kN (SD, 0.2). Fatigue test with 500,000 cycles was passed. In vitro radiological evaluation demonstrated good compatibility with X-ray and CT scan examinations. In vivo test employed eight pigs weighing 50 kg each. Instrumented lumbar spine fusion of L3/4 and L4/5 with these cages was performed on each pig. After 3 months, excellent bone integration property was demonstrated by direct contact of the cage with the host bone and newly formed bone. No inflammatory cells were found around the implant. Cages packed with two different graft materials (autograft and COLLOSS) achieved the same new bone formation. The present study proved that coating tantalum on top of the carbon-based implant is feasible, and good bone integration could be achieved.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge