Polish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
The American journal of physiology 1988-Apr

Quantification of arteriolar density and embolization by microspheres in rat myocardium.

Tylko zarejestrowani użytkownicy mogą tłumaczyć artykuły
Zaloguj się Zarejestruj się
Link zostanie zapisany w schowku
P A Wieringa
H G Stassen
J D Laird
J A Spaan

Słowa kluczowe

Abstrakcyjny

We developed a technique for in vitro determination of arteriolar densities. Hearts, obtained from anesthetized rats and perfused by the Langendorff method, were fully dilated with adenosine and were arrested with an elevated potassium concentration. After a stabilization period, the hearts were perfused with a buffered fixative for some minutes to obtain a nonvital vasculature. After fixation, perfusion was switched back to control for some minutes. The hearts were then perfused with a medium containing a low concentration of microspheres: either pollen grains [Urtica dioica (15.4 microns), Betula (23.5 microns), or Phleum pratense (36.5 microns)] or polystyrene microspheres (15 microns). The perfusion was switched back to the standard medium after flow had been reduced to between 83 and 57% of control flow. Microscopic observations of microsections revealed that the percentages of arterioles embolized by one microsphere were 64% for the 15.4-microns, 74% for the 15-microns, 78% for the 23.5-microns, and 72% for the 36.5-microns microspheres. The percentages of arterioles embolized with two microspheres were 20, 15, 15, and 16%, respectively. The arteriolar densities were calculated from the total fractional reduction in coronary flow, the amount of microspheres injected, the wet heart weight, and the degree of occupancy, which corrects for the multiple embolization of the arterioles. The arteriolar densities in the rat hearts were 162.4 +/- 54.9 mg-1 (N = 6) for polystyrene microspheres of 15 microns, 161.5 +/- 81.1 mg-1 (N = 15) for 15.4-microns microspheres, 31.6 +/- 7.8 mg-1 (N = 9) for 23.5-microns microspheres, and 13.0 +/- 2.4 mg-1 (N = 8) for 36.5-microns microspheres.

Dołącz do naszej strony
na Facebooku

Najbardziej kompletna baza danych ziół leczniczych poparta naukowo

  • Działa w 55 językach
  • Ziołowe leki poparte nauką
  • Rozpoznawanie ziół na podstawie obrazu
  • Interaktywna mapa GPS - oznacz zioła na miejscu (wkrótce)
  • Przeczytaj publikacje naukowe związane z Twoim wyszukiwaniem
  • Szukaj ziół leczniczych po ich działaniu
  • Uporządkuj swoje zainteresowania i bądź na bieżąco z nowościami, badaniami klinicznymi i patentami

Wpisz objaw lub chorobę i przeczytaj o ziołach, które mogą pomóc, wpisz zioło i zobacz choroby i objawy, na które są stosowane.
* Wszystkie informacje oparte są na opublikowanych badaniach naukowych

Google Play badgeApp Store badge