Romanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)

OCTA Metrics Repeatability and Reproducibility in Different Disorders

Numai utilizatorii înregistrați pot traduce articole
Log In / Înregistrare
Linkul este salvat în clipboard
stareÎncă nu recrutezi
Sponsorii
Tanta University

Cuvinte cheie

Abstract

Retinal imaging is a corner stone in diagnosis of most retinal disorders. Standard imaging techniques e.g. fluorescein angiography and color fundus photography have a lot of limitations including limited resolution, invasive nature in cases of fluorescein angiography, and inability to segment the retina, accordingly, and only 2D image is provided.
Optical coherence tomography angiography (OCTA) is a recent noninvasive imaging technique that allows for volumetric visualization of eye vasculature. OCTA has shown promise in better elucidating the pathophysiology of several retinal vascular diseases. Swept-source OCTA uses long wavelength ̰ 1,050nm, which can penetrate through deeper layers of the eye and can traverse opacities of media such as cataracts, hemorrhages and vitreous opacities.
Optical coherence tomographic angiograms can further be manually or automatically segmented with preprogrammed software to highlight individual layers of the retina, optic nerve head choriocapillaris, and choroid. The user can either analyze en face images extending from the inner limiting membrane to choroid or use automated views to locate a vascular or structural lesion within the retina.
Different quantitative metrics has been extracted from enface OCTA images including vessel density, FAZ area, choriocapillaries flow deficit, intercapillary area and fractal dimension. These metrics are helpful in evaluation the retinal perfusion and used by physicians to assess various retinal vascular disorders.
Although some previous literatures had discussed the repeatability of OCTA metrics, however, comprehensive evaluation of widely used metrics in various retinal condition has not be done. Additionally, recent data suggest that various methods of calculation of these metrics my yield final different results of the same metric.

Descriere

This will be prospective cross-sectional study. This research will be done in the period between 1 August and 31 December 2020 and will include 80 eyes from patients with following disorders:

Group 1: Patients with diabetic retinopathy Group 2: Patients with myopia Group 3: patients with choroidal neovascularization Group 4: control eyes with no retinal disease. Inclusion criteria: Patients above 18 years in age with any of above retinal condition and clear media allowing for imaging will be included.

Exclusion criteria will include; Maculopathies (hereditary or acquired), optic nerve head pathologies (tilted disc, drusen, optic disc edema, atrophy, etc.), optic neuropathies (demyelinating, infectious, ischemic, etc.), adjusted IOP for central corneal thickness more than 21 mmHg, surgery-induced corneal edema and dense cataracts that can disrupt images, history of vasoactive agents (calcium antagonists, nitric oxide, etc.) use, systemic diseases (vasculitis, diabetes mellitus, hypertension, etc.) and any previous ocular surgery, patients with bad quality images or complicated surgeries will be excluded.

All patients will be subject to Full ophthalmologic examination and OCTA imaging. High-quality 3 x 3 mm and 6 x 6 mm OCTA macular scans and 4.5 × 4.5-mm papillary scan with strong signal-noise ratio and adequate centration on the fovea and optic nerve head respectively will be selected.

For each patient 10 successive scans will be generated to allow for the analysis of repeatability. Patient will be imaged in the same day at two different OCTA devices Dri Triton (Topcon, Japan) and Cirrus OCT (Zeiss, USA) to investigate the reproducibility of the measurements.

Automated segmentation will be used to evaluate superficial and deep capillary retinal plexus projections. If errors in segmentation were detected, manual correction would be performed. The superficial retinal capillary plexus (SCP) was delineated with an inner boundary at the internal limiting membrane (ILM) and an outer boundary 10 µm inside the inner plexiform layer (IPL). The deep retinal capillary plexus (DCP) was segmented with an inner boundary 10 µm inside the IPL and an outer boundary at 10 µm beneath the outer plexiform layer (OPL). In addition, the total retinal capillary plexus (TCP) was manually customized by selecting the inner boundary at the ILM and the outer boundary set at 40 µm above the retinal pigment epithelium (RPE) to avoid any flow signals from choriocapillaries.

We will evaluate the following metric from enface OCT angiogram; vessel density, vessel density, intercapillary area, fractal dimension and skeletonized vessel density.

Every included patient in this study will have unique code number referring to the file where all his data will be kept confidential. Only macula and optic disc will be imaged. Additionally, patients` personal data will be hidden during using of these images. All patients` data will be used for scientific research only and will be kept totally confidential. Comprehensive explanation of all aspects of this study will be given to patients before their participation in it, an informed consent will be obtained from the patients before their enrolment in the study. Although no documented adverse effects from OCTA imaging on the patients to date, however, any unexpected risks appeared during the research will be cleared to the participants and the ethical committee on time.

Statistical analysis will be performed using SPSS software (version 25; SPSS, Inc., Chicago, IL, USA). the intraclass correlation coefficient (ICC) and coefficient of variation (CV) will be calculated. ICC is the correlation between two variables measured at the same time point, with values ranging from 0 to 1 (<0.40, poor; 0.40-0.59, fair; 0.60-0.74, good; 0.75-1.00, excellent). The CV (%) will be calculated as 100 × standard deviation/overall mean, and a value <10% represents good repeatability of the measurement.

Datele

Ultima verificare: 06/30/2020
Primul depus: 07/23/2020
Inscriere estimată trimisă: 07/23/2020
Prima postare: 07/27/2020
Ultima actualizare trimisă: 07/23/2020
Ultima actualizare postată: 07/27/2020
Data actuală de începere a studiului: 07/31/2020
Data estimată de finalizare primară: 12/30/2020
Data estimată de finalizare a studiului: 07/30/2021

Stare sau boală

Diabetic Retinopathy
Myopia
Choroidal Neovascularization
Healthy

Intervenție / tratament

Diagnostic Test: Optical coherence tomography angiography

Fază

-

Grupuri de brațe

BraţIntervenție / tratament
Diabetic retinopathy Group
Patients with non-proliferative and proliferative diabetic retinopathy with clear media will be recruited.
Myopia Group
Patients with different grades of myopia, with accurate segmentation will be recruited
Choroidal neovascularization group
Patients with active choroidal vascularization without scarring will be recruited
Healthy controls
Healthy individuals without retinal disorders will be included for comaprison

Criterii de eligibilitate

Vârste eligibile pentru studiu 18 Years La 18 Years
Sexe eligibile pentru studiuAll
Metoda de eșantionareNon-Probability Sample
Acceptă voluntari sănătoșida
Criterii

Inclusion Criteria:

- Patients 18 years or above, that fall in any of the study groups

- Clear media allowing for imaging

Exclusion Criteria:

- Maculopathies (hereditary or acquired)

- Optic nerve head pathologies (tilted disc, drusen, optic disc edema, atrophy, etc.)

- Optic neuropathies (demyelinating, infectious, ischemic, etc.),

- corneal edema and dense cataracts that can disrupt images

- history of vasoactive agents (calcium antagonists, nitric oxide, etc.)

- systemic diseases (vasculitis, diabetes mellitus, hypertension, etc.)

- Previous ocular surgery

Rezultat

Măsuri de rezultate primare

1. The intraclass correlation coefficient (ICC) [5 months]

ICC is the correlation between two variables measured at the same time point, with values ranging from 0 to 1 (<0.40, poor; 0.40-0.59, fair; 0.60-0.74, good; 0.75-1.00, excellent).

2. coefficient of variation (CV) [5 months]

The CV (%) will be calculated as 100 × standard deviation/overall mean, and a value <10% represents good repeatability of the measurement.

Alăturați-vă paginii
noastre de facebook

Cea mai completă bază de date cu plante medicinale susținută de știință

  • Funcționează în 55 de limbi
  • Cure pe bază de plante susținute de știință
  • Recunoașterea ierburilor după imagine
  • Harta GPS interactivă - etichetați ierburile în locație (în curând)
  • Citiți publicațiile științifice legate de căutarea dvs.
  • Căutați plante medicinale după efectele lor
  • Organizați-vă interesele și rămâneți la curent cu noutățile de cercetare, studiile clinice și brevetele

Tastați un simptom sau o boală și citiți despre plante care ar putea ajuta, tastați o plantă și vedeți boli și simptome împotriva cărora este folosit.
* Toate informațiile se bazează pe cercetări științifice publicate

Google Play badgeApp Store badge