American Journal of Emergency Medicine 2013-Oct

A comparison of two techniques for tungsten carbide ring removal.

Numai utilizatorii înregistrați pot traduce articole
Log In / Înregistrare
Linkul este salvat în clipboard
Carolyn L Gardiner
Krista Handyside
Justin Mazzillo
Mandy J Hill
Eric F Reichman
Yashwant Chathampally
Brent R King

Cuvinte cheie

Abstract

BACKGROUND

Emergency physicians may have difficulty removing modern rings made of hard metals such as titanium and tungsten carbide. These metals are exceptionally difficult or impossible to remove using standard ring cutters. Numerous alternative techniques for removal have been described, including the "umbilical tape" or "string technique" and, in the case of tungsten carbide, breaking the ring using locking pliers.

OBJECTIVE

We sought to compare the speed and effectiveness of tungsten carbide ring removal using these two techniques.

METHODS

Ten tungsten carbide rings were placed upon the finger of a standard medical simulation mannequin. The rings chosen were one-half size smaller than the mannequin's finger. Edema distal to the ring was simulated using foam tape. A single novice operator performed 10 trials using each of the techniques after a 10-minute orientation session. The success or failure of the technique and the time for removal were recorded for each trial. The mean removal times for the trials were compared using a paired t test.

RESULTS

All trials were successful. The rings were removed substantially faster using the locking pliers method (mean 23.1 seconds [95% CI 15.4-30.8] vs. mean 135.4 seconds [95% CI 130.2-150.6]). However, the locking pliers technique destroyed all rings and caused sharp ring fragments to be thrown up to 37 in.

CONCLUSIONS

Both the umbilical tape or string technique and the locking pliers technique successfully removed tungsten carbide rings in our model. The locking pliers technique is significantly faster but destroys the ring and creates potentially harmful shrapnel.

Alăturați-vă paginii
noastre de facebook

Cea mai completă bază de date cu plante medicinale susținută de știință

  • Funcționează în 55 de limbi
  • Cure pe bază de plante susținute de știință
  • Recunoașterea ierburilor după imagine
  • Harta GPS interactivă - etichetați ierburile în locație (în curând)
  • Citiți publicațiile științifice legate de căutarea dvs.
  • Căutați plante medicinale după efectele lor
  • Organizați-vă interesele și rămâneți la curent cu noutățile de cercetare, studiile clinice și brevetele

Tastați un simptom sau o boală și citiți despre plante care ar putea ajuta, tastați o plantă și vedeți boli și simptome împotriva cărora este folosit.
* Toate informațiile se bazează pe cercetări științifice publicate

Google Play badgeApp Store badge