Romanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatographic Science 2017-Oct

Reliable GC Method for Related Substances in Divalproex Sodium Drug.

Numai utilizatorii înregistrați pot traduce articole
Log In / Înregistrare
Linkul este salvat în clipboard
S Raghavender Reddy
K Hussain Reddy
P Madhava Reddy
G Amarnatha Reddy
M Narendra Kumar
Hemant Kumar Sharma

Cuvinte cheie

Abstract

A specific GC method has been developed, optimized and validated for the determination of seven related substances namely N,N-dimethyl valpronamide, valeric acid, 2-methyl valeric acid, 2-ethyl valeric acid, 2-isopropyl valeric acid, 2-n-butyl valeric acid and 2-propyl-2-pentenoic acid in divalproex sodium (DPS) drug substance. Chromatographic separations of these seven impurities were achieved on DB-FFAP column (30 m × 0.53 mm, 1.0 μm), which consists nitroterephthalic acid modified polyethylene glycol material as stationary phase. DPS is a coordination complex of the sodium valproate and valproic acid (VPA). Nonanoic acid is used as internal standard. All the seven related substances, VPA and nonanoic acid were extracted into dichloromethane and monitored by GC with flame ionization detector. The performance of the developed method was assessed by evaluating specificity, linearity, sensitivity, precision, accuracy and robustness. Forced degradation experiments were conducted to evaluate the degradation behavior of DPS. The established limits of detection (LODs) and limits of quantification (LOQs) values for the related substances were in the ranges of 4-5 and 12-15 μg mL-1, respectively. Further, for VPA, LOD and LOQ values were 4 and 12 μg mL-1, respectively. The correction factors of these related substances with respect to VPA and lie between 0.92 and 1.44. The average recoveries were in the range of 92.4-108.4%.

Alăturați-vă paginii
noastre de facebook

Cea mai completă bază de date cu plante medicinale susținută de știință

  • Funcționează în 55 de limbi
  • Cure pe bază de plante susținute de știință
  • Recunoașterea ierburilor după imagine
  • Harta GPS interactivă - etichetați ierburile în locație (în curând)
  • Citiți publicațiile științifice legate de căutarea dvs.
  • Căutați plante medicinale după efectele lor
  • Organizați-vă interesele și rămâneți la curent cu noutățile de cercetare, studiile clinice și brevetele

Tastați un simptom sau o boală și citiți despre plante care ar putea ajuta, tastați o plantă și vedeți boli și simptome împotriva cărora este folosit.
* Toate informațiile se bazează pe cercetări științifice publicate

Google Play badgeApp Store badge