Journal of the Medical Association of Thailand = Chotmaihet thangphaet 2004-Jun

Maternal satisfaction to epidural and spinal anesthesia for cesarean section.

Samo registrirani uporabniki lahko prevajajo članke
Prijava / prijava
Povezava se shrani v odložišče
Wacharin Sindhvananda
Ruenreong Leelanukrom
Oraluxna Rodanant
Pin Sriprajittichai

Ključne besede

Povzetek

OBJECTIVE

The differences between epidural (EA) and spinal (SA) anesthesia that can affect maternal satisfaction are the procedures, quality of anesthesia and postoperative events. Dominantly, postoperative events such as postdural puncture headache, pruritus and nausea or vomiting after spinal anesthesia are claimed to be its disadvantages. However, maternal satisfactory perception to theses two techniques has not been revealed. The authors' purpose was to compare maternal satisfaction regarding the techniques and their outcomes between EA and SA by the developed valid and reliable tool.

METHODS

Patients were randomly classified into two groups: epidural (Group E, n=56) and spinal (Group S, n = 58). Epidural and spinal anesthesia were administered with bupivacaine, 20 mL 0.5% with 1:200,000 epinephrine combined with two doses of 5 mg morphine and hyperbaric bupivacaine 2.2-2.4 mL 0.5% combined with 0.2 mg morphine respectively. Guidelines for treatment of intraoperative and postoperative events, which might be the confounding factors, were set up. Maternal satisfaction was evaluated by the 11-item, qualified, self-administered questionnaire comprised of 4 common factors. The score of 0-10 Visual analog scale was used to access the degree of satisfaction. Trained personnel performed data collections in the post-anesthesia care unit and ward. The means of the factor and total satisfaction scores were compared between the two groups by Mann Whitney U test. A p-value < 0.05 considered significant.

RESULTS

There was no statistical difference in the factor scores between the two groups. The total satisfactory score was 89.48 +/- 9.31 and 90.03 +/- 11.26 in Group E and S respectively. No statistical difference of the total satisfaction score was detected.

CONCLUSIONS

There was no difference in maternal satisfaction regarding to the techniques and the outcomes between EA and SA.

Pridružite se naši
facebook strani

Najbolj popolna baza zdravilnih zelišč, podprta z znanostjo

  • Deluje v 55 jezikih
  • Zeliščna zdravila, podprta z znanostjo
  • Prepoznavanje zelišč po sliki
  • Interaktivni GPS zemljevid - označite zelišča na lokaciji (kmalu)
  • Preberite znanstvene publikacije, povezane z vašim iskanjem
  • Iščite zdravilna zelišča po njihovih učinkih
  • Organizirajte svoje interese in bodite na tekočem z raziskavami novic, kliničnimi preskušanji in patenti

Vnesite simptom ali bolezen in preberite o zeliščih, ki bi lahko pomagala, vnesite zelišče in si oglejte bolezni in simptome, proti katerim se uporablja.
* Vse informacije temeljijo na objavljenih znanstvenih raziskavah

Google Play badgeApp Store badge