Slovenian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
British Journal of Radiology 1992-Mar

The dose-rate effect in interstitial brachytherapy: a controversy resolved.

Samo registrirani uporabniki lahko prevajajo članke
Prijava / prijava
Povezava se shrani v odložišče
E J Hall
D J Brenner

Ključne besede

Povzetek

Low-dose-rate interstitial implants generally involve a range of dose rates varying from about 0.3 to 1.5 Gy/h. It has been a matter of some debate as to whether such a variation in dose rate has any impact on clinical results, i.e. whether implant treatment time needs to be taken into account when prescribing the treatment dose. In particular, Paterson and Ellis both published data based on clinical experience suggesting that the prescribed dose should vary with overall treatment time, whereas the Paris school suggested that isoeffect dose should not be varied for treatment times between 3 and 8 days. Experimental radiobiological data obtained in vitro and in vivo imply a significant change in biological effectiveness over this range of dose rates with a greater variation for normal-tissue late effects than for tumour control. We show, based on radiological considerations and model calculations, that the disagreement between the two schools in their recommendations for generating isoeffect doses for different treatment times was a result of two factors. First, the Paterson recommendation was unequivocally based on matching limiting late effects, whereas the Paris system recommendations were based on an analysis of a combination of late and early effects. Second, the Paterson recommendations were based on a dosimetry system in which the dose rate does not change greatly with tumour volume, whereas the Paris recommendations were based on a dosimetric system in which dose rate is correlated with tumour volume, which in turn is correlated with changes in both tumour control and, especially, necrosis.

Pridružite se naši
facebook strani

Najbolj popolna baza zdravilnih zelišč, podprta z znanostjo

  • Deluje v 55 jezikih
  • Zeliščna zdravila, podprta z znanostjo
  • Prepoznavanje zelišč po sliki
  • Interaktivni GPS zemljevid - označite zelišča na lokaciji (kmalu)
  • Preberite znanstvene publikacije, povezane z vašim iskanjem
  • Iščite zdravilna zelišča po njihovih učinkih
  • Organizirajte svoje interese in bodite na tekočem z raziskavami novic, kliničnimi preskušanji in patenti

Vnesite simptom ali bolezen in preberite o zeliščih, ki bi lahko pomagala, vnesite zelišče in si oglejte bolezni in simptome, proti katerim se uporablja.
* Vse informacije temeljijo na objavljenih znanstvenih raziskavah

Google Play badgeApp Store badge