JACC: Cardiovascular Imaging 2017-Oct

A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.

Vetëm përdoruesit e regjistruar mund të përkthejnë artikuj
Identifikohuni Regjistrohu
Lidhja ruhet në kujtesën e fragmenteve
Yoshio Maeno
Yigal Abramowitz
Hiroyuki Kawamori
Yoshio Kazuno
Shunsuke Kubo
Nobuyuki Takahashi
Geeteshwar Mangat
Kazuaki Okuyama
Mohammad Kashif
Tarun Chakravarty

Fjalë kyçe

Abstrakt

OBJECTIVE

This study sought to develop a robust and definitive risk model for new permanent pacemaker implantation (PPMI) after SAPIEN 3 (third generation balloon expandable valve) (Edwards Lifesciences, Irvine, California) transcatheter aortic valve replacement (third generation balloon expandable valve TAVR), including calcification in the aortic-valvular complex (AVC).

BACKGROUND

The association between calcium in the AVC and need for PPMI is poorly delineated after third generation balloon expandable valve TAVR.

METHODS

At Cedars-Sinai Heart Institute in Los Angeles, California, a total of 240 patients with severe aortic stenosis underwent third generation balloon expandable valve TAVR and had contrast computed tomography. AVC was characterized precisely by leaflet sector and region.

RESULTS

The total new PPMI rate was 14.6%. On multivariate analysis for predictors of PPMI, pre-procedure third generation balloon expandable valve TAVR, right bundle branch block (RBBB), shorter membranous septum (MS) length, and noncoronary cusp device-landing zone calcium volume (NCC-DLZ CA) were included. Predictive probabilities were generated using this logistic regression model. If 3 pre-procedural risk factors were present, the c-statistic of the model for PPMI was area under the curve of 0.88, sensitivity of 77.1%, and specificity of 87.1%; this risk model had high negative predictive value (95.7%). The addition of the procedural factor of device depth to the model, with the parameter of difference between implantation depth and MS length, combined with RBBB and NCC-DLZ CA increased the c-statistic to 0.92, sensitivity to 94.3%, specificity to 83.8%, and negative predictive value to 98.8% CONCLUSIONS: By using a precise characterization of distribution of calcification in the AVC in a single-center, retrospective study, NCC-DLZ CA was found to be an independent predictor of new PPMI post-third generation balloon expandable valve TAVR. The findings also reinforce the importance of short MS length, pre-existing RBBB, and ventricular implantation depth as important synergistic PPMI risk factors. This risk model will need validation by future prospective multicenter studies.

Bashkohuni në faqen
tonë në facebook

Baza e të dhënave më e plotë e bimëve medicinale e mbështetur nga shkenca

  • Punon në 55 gjuhë
  • Kurime bimore të mbështetura nga shkenca
  • Njohja e bimëve nga imazhi
  • Harta GPS interaktive - etiketoni bimët në vendndodhje (së shpejti)
  • Lexoni botime shkencore në lidhje me kërkimin tuaj
  • Kërkoni bimë medicinale nga efektet e tyre
  • Organizoni interesat tuaja dhe qëndroni në azhurnim me kërkimet e lajmeve, provat klinike dhe patentat

Shkruani një simptomë ose një sëmundje dhe lexoni në lidhje me barërat që mund të ndihmojnë, shtypni një barishte dhe shikoni sëmundjet dhe simptomat që përdoren kundër.
* I gjithë informacioni bazohet në kërkimin shkencor të botuar

Google Play badgeApp Store badge