Albanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2002-Dec

Analytical performance of a miniature cylindrical ion trap mass spectrometer.

Vetëm përdoruesit e regjistruar mund të përkthejnë artikuj
Identifikohuni Regjistrohu
Lidhja ruhet në kujtesën e fragmenteve
Leah S Riter
Yanan Peng
Robert J Noll
Garth E Patterson
Tenna Aggerholm
R Graham Cooks

Fjalë kyçe

Abstrakt

The analytical performance of a fieldable cylindrical ion trap (CIT)-based miniature mass spectrometer is described. A detailed description of the instrument itself is to be found in the immediately preceding paper (Patterson, G. E.; Guymon, A. J.; Riter, L S.; Everly, M.; Griep-Raming, J.; Laughlin, B. C.; Ouyang, Z.; Cooks, R. G., Miniature Cylindrical Ion Trap Mass Spectrometer, Anal. Chem. 2002, 24, 6145-6153). Applications employing the MS/MS and MSn capabilities of the miniature instrument and analytical performance criteria are given here. The limit of detection for methyl salicylate, introduced as the pure vapor, is estimated as 1 pg. The resolution, R = m/delta m, where delta m, measured as full width at half-maximum, is estimated as 100. Monitoring of organic compounds in air is performed using a permeation membrane introduction device coupled to the mass spectrometer. Water monitoring is performed using an external membrane introduction mass spectrometry (MIMS) system, with acetophenone and toluene serving as model compounds. Data are given for chemical warfare agent simulants, methyl salicylate, and dimethyl methyl phosphonate (DMMP) in air. On-line detection of menthol vapor emitted from a cough drop is reported. Methyl salicylate in air gives a recognizable mass spectrum at 400 ppb in the ambient system, while use of a heated membrane brings the detection limit down to 10 ppb.

Bashkohuni në faqen
tonë në facebook

Baza e të dhënave më e plotë e bimëve medicinale e mbështetur nga shkenca

  • Punon në 55 gjuhë
  • Kurime bimore të mbështetura nga shkenca
  • Njohja e bimëve nga imazhi
  • Harta GPS interaktive - etiketoni bimët në vendndodhje (së shpejti)
  • Lexoni botime shkencore në lidhje me kërkimin tuaj
  • Kërkoni bimë medicinale nga efektet e tyre
  • Organizoni interesat tuaja dhe qëndroni në azhurnim me kërkimet e lajmeve, provat klinike dhe patentat

Shkruani një simptomë ose një sëmundje dhe lexoni në lidhje me barërat që mund të ndihmojnë, shtypni një barishte dhe shikoni sëmundjet dhe simptomat që përdoren kundër.
* I gjithë informacioni bazohet në kërkimin shkencor të botuar

Google Play badgeApp Store badge