Albanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Infection Control and Hospital Epidemiology 1991-May

Disinfection practices for endoscopes and other semicritical items.

Vetëm përdoruesit e regjistruar mund të përkthejnë artikuj
Identifikohuni Regjistrohu
Lidhja ruhet në kujtesën e fragmenteve
W A Rutala
E P Clontz
D J Weber
K K Hoffmann

Fjalë kyçe

Abstrakt

OBJECTIVE

To determine the disinfection practices employed by North Carolina hospitals for endoscopes and other semicritical patient care items and to discuss minimally acceptable disinfection procedures for these items.

METHODS

A survey questionnaire was mailed to all North Carolina hospitals to identify their disinfection practices, and a literature review was conducted to ascertain studies that evaluated disinfection techniques for certain semicritical items.

METHODS

Questionnaires were returned by 107 of 167 (64%) North Carolina acute-care hospitals.

RESULTS

Most hospitals (91%) used a glutaraldehyde-based disinfectant (59%, 2% glutaraldehyde; 29%, 0.13% glutaraldehyde-0.44% phenol-0.08% phenate; 3%, either); half (51%) of the hospitals immersed the endoscope into disinfectant for greater than or equal to 20 minutes, but 44% immersed for less than or equal to 10 minutes; nearly all hospitals (97%) disinfected endoscopes at room temperature. Hospitals rinsed the endoscope with sterile water (16%), tap water (54%), tap water followed by alcohol rinse (27%), or other (2%); 58% of the hospitals treated endoscopes from patients infected with human immunodeficiency virus (HIV), hepatitis B virus (HBV), or Mycobacterium tuberculosis differently (81%, ethylene oxide [ETO] sterilization; 10%, increased exposure time; 10%, other). Twenty percent of the hospitals used an automated washer for processing endoscopic instruments. Rigid endoscopes (e.g., arthroscopes, laparoscopes) were primarily high-level disinfected (57%), ETO sterilized (17%), or either (13%). The disinfection strategies for other semi-critical items (e.g., applanation tonometers, cryosurgical instruments, and diaphragm fitting rings) were highly variable for the responding hospitals.

CONCLUSIONS

This survey indicated the presence of a wide variety of practices for handling semicritical patient care items, many of which are inconsistent with current recommendations. To help establish minimally acceptable disinfection procedures for some patient care instruments (e.g., arthroscopes, laparoscopes, tonometers), the scientific literature was reviewed and recommendations were made.

Bashkohuni në faqen
tonë në facebook

Baza e të dhënave më e plotë e bimëve medicinale e mbështetur nga shkenca

  • Punon në 55 gjuhë
  • Kurime bimore të mbështetura nga shkenca
  • Njohja e bimëve nga imazhi
  • Harta GPS interaktive - etiketoni bimët në vendndodhje (së shpejti)
  • Lexoni botime shkencore në lidhje me kërkimin tuaj
  • Kërkoni bimë medicinale nga efektet e tyre
  • Organizoni interesat tuaja dhe qëndroni në azhurnim me kërkimet e lajmeve, provat klinike dhe patentat

Shkruani një simptomë ose një sëmundje dhe lexoni në lidhje me barërat që mund të ndihmojnë, shtypni një barishte dhe shikoni sëmundjet dhe simptomat që përdoren kundër.
* I gjithë informacioni bazohet në kërkimin shkencor të botuar

Google Play badgeApp Store badge