Albanian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Neurosurgery 1989-Mar

Magnetic movement of a brain thermoceptor.

Vetëm përdoruesit e regjistruar mund të përkthejnë artikuj
Identifikohuni Regjistrohu
Lidhja ruhet në kujtesën e fragmenteve
M A Howard
M S Grady
R C Ritter
G T Gillies
E G Quate
J A Molloy

Fjalë kyçe

Abstrakt

Hyperthermia has significant potential as an adjuvant form of brain tumor therapy. Current intracranial hyperthermia methods, however, are limited in their ability to control spatiotemporal thermal distribution. A stereotaxic magnetic movement system that may be capable of heating discrete regions of brain to a preselected temperature is described. With this system, a ferromagnetic object (referred to as a thermoceptor) is directed through the brain by an external drive magnet. Real time thermoceptor position is monitored with biplanar fluoroscopy and superimposed on a preoperative magnetic resonance imaging scan using a computer. Once in position, the thermoceptor can be inductively heated by externally generated radiofrequency signals. Experiments on the magnetic drive and imaging aspects of this system have been conducted in vitro and in vivo. Mechanical studies of cadaver dog brains revealed that a mean force of 0.07 +/- 0.03 N was required to move a 3-mm diameter sphere through brain at a speed of less than 1 cm/15 s. A cranial phantom with mechanical properties similar to brain was constructed of gelatin and Plexiglas. With the use of a "neck loop" design drive magnet with a maximum magnetic field strength of 0.10 T, a 3 x 3 mm cylindrical neodymium iron boron thermoceptor was smoothly directed through the phantom in two dimensions. Additional experiments were conducted with a larger drive magnet in five anesthetized dogs. Neodymium iron boron and samarium cobalt thermoceptors of various shapes and sizes were placed into the cerebral cortex through a burr hole, then directed with the drive magnet. Fluoroscopy was used to follow the thermoceptor movements.(ABSTRACT TRUNCATED AT 250 WORDS)

Bashkohuni në faqen
tonë në facebook

Baza e të dhënave më e plotë e bimëve medicinale e mbështetur nga shkenca

  • Punon në 55 gjuhë
  • Kurime bimore të mbështetura nga shkenca
  • Njohja e bimëve nga imazhi
  • Harta GPS interaktive - etiketoni bimët në vendndodhje (së shpejti)
  • Lexoni botime shkencore në lidhje me kërkimin tuaj
  • Kërkoni bimë medicinale nga efektet e tyre
  • Organizoni interesat tuaja dhe qëndroni në azhurnim me kërkimet e lajmeve, provat klinike dhe patentat

Shkruani një simptomë ose një sëmundje dhe lexoni në lidhje me barërat që mund të ndihmojnë, shtypni një barishte dhe shikoni sëmundjet dhe simptomat që përdoren kundër.
* I gjithë informacioni bazohet në kërkimin shkencor të botuar

Google Play badgeApp Store badge