Improvement on the auxiliary total artificial heart (ATAH) left chamber design.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Aron Andrade
Jeison Fonseca
Daniel Legendre
Denys Nicolosi
Jose Biscegli
Marcos Pinotti
Yukio Ohashi
Yukihiko Nosé

Nyckelord

Abstrakt

The auxiliary total artificial heart (ATAH) is an electromechanically driven artificial heart with reduced dimensions, which is able to be implanted in the right thoracic or abdominal cavities of an average human patient without removing the natural heart or the heart neurohumoral inherent control mechanism for the arterial pressure. This device uses a brushless direct current motor and a mechanical actuator (roller screw) to move two diaphragms. The ATAH's beating frequency is regulated through the change of the left preload, based on Frank-Starling's law, assisting the native heart in obtaining adequate blood flow. The ATAH left and right stroke volumes are 38 ml and 34 ml, respectively, giving approximately 5 L/min of cardiac output at 160 bpm. Flow visualization studies were performed in critical areas on the ATAH left chamber. A closed circuit loop was used with water and glycerin (37%) at 25 degrees C. Amberlite particles (80 mesh) were illuminated by a 1 mm planar helium-neon laser light. With left mean preload fixed at 10 mm Hg and the afterload at 100 mm Hg, the heart rate varied from 60 to 200 bpm. Two porcine valves were used on the inlet and outlet ports. The flow pattern images were obtained using a color micro-camera and a video recorder. Subsequently, these images were digitized using a PC computer. A persistent stagnant flow was detected in the left chamber inlet port. After improvement on the left chamber design, this stagnant flow disappeared.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge