Swedish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of the Medical Association of Thailand = Chotmaihet thangphaet 2004-Jun

Maternal satisfaction to epidural and spinal anesthesia for cesarean section.

Endast registrerade användare kan översätta artiklar
Logga in Bli medlem
Länken sparas på Urklipp
Wacharin Sindhvananda
Ruenreong Leelanukrom
Oraluxna Rodanant
Pin Sriprajittichai

Nyckelord

Abstrakt

OBJECTIVE

The differences between epidural (EA) and spinal (SA) anesthesia that can affect maternal satisfaction are the procedures, quality of anesthesia and postoperative events. Dominantly, postoperative events such as postdural puncture headache, pruritus and nausea or vomiting after spinal anesthesia are claimed to be its disadvantages. However, maternal satisfactory perception to theses two techniques has not been revealed. The authors' purpose was to compare maternal satisfaction regarding the techniques and their outcomes between EA and SA by the developed valid and reliable tool.

METHODS

Patients were randomly classified into two groups: epidural (Group E, n=56) and spinal (Group S, n = 58). Epidural and spinal anesthesia were administered with bupivacaine, 20 mL 0.5% with 1:200,000 epinephrine combined with two doses of 5 mg morphine and hyperbaric bupivacaine 2.2-2.4 mL 0.5% combined with 0.2 mg morphine respectively. Guidelines for treatment of intraoperative and postoperative events, which might be the confounding factors, were set up. Maternal satisfaction was evaluated by the 11-item, qualified, self-administered questionnaire comprised of 4 common factors. The score of 0-10 Visual analog scale was used to access the degree of satisfaction. Trained personnel performed data collections in the post-anesthesia care unit and ward. The means of the factor and total satisfaction scores were compared between the two groups by Mann Whitney U test. A p-value < 0.05 considered significant.

RESULTS

There was no statistical difference in the factor scores between the two groups. The total satisfactory score was 89.48 +/- 9.31 and 90.03 +/- 11.26 in Group E and S respectively. No statistical difference of the total satisfaction score was detected.

CONCLUSIONS

There was no difference in maternal satisfaction regarding to the techniques and the outcomes between EA and SA.

Gå med på vår
facebook-sida

Den mest kompletta databasen med medicinska örter som stöds av vetenskapen

  • Fungerar på 55 språk
  • Växtbaserade botemedel som stöds av vetenskap
  • Örter igenkänning av bild
  • Interaktiv GPS-karta - märka örter på plats (kommer snart)
  • Läs vetenskapliga publikationer relaterade till din sökning
  • Sök efter medicinska örter efter deras effekter
  • Organisera dina intressen och håll dig uppdaterad med nyheterna, kliniska prövningar och patent

Skriv ett symptom eller en sjukdom och läs om örter som kan hjälpa, skriv en ört och se sjukdomar och symtom den används mot.
* All information baseras på publicerad vetenskaplig forskning

Google Play badgeApp Store badge