Repeatability and Reproducibility of Quantitative MRCP

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
HaliImekamilika
Wadhamini
Perspectum Diagnostics Ltd

Maneno muhimu

Kikemikali

This study aims to determine the repeatability and reproducibility of Quantitative Magnetic Resonance Cholangiopancreatography (MRCP).
Imaging scientists at Perspectum Diagnostics have developed a hessian-based mathematical model to enhance conventional MRCP to a 3D geometric model of the biliary tree, 'Quantitative MRCP'. This enables advanced quantitative measurement of bile duct width, orientation, branching point and curvative metrics.
The technology has been validated against 3D printed phantoms for accuracy, and early clinical research has demonstrated the technology has potential for clinical impact, with improvement in radiologist performance versus conventional non-enhanced MRCP imaging (Vikal et al 2017).
Quantitative MRCP aims to act as a tool to not only improve assessment of the current status of the biliary tree, but also act as a mechanism to track change within the ducts. Thus, it must be established that any change between scans is due to change in the physiology of the individual and not due to a quirk or fault of the technology.
In order to achieve this a series of scans will be performed on an individual over a short period of time, for which the condition of the biliary tree within that individual can be assumed to be constant. Between each scan, subject and coil repositioning will occur.
The study will recruit a group of adult volunteers, from both diseased groups and healthy groups in order to achieve a range of physiological biliary metrics.

Maelezo

Biliary-related conditions, such as autoimmune conditions Primary Biliary Cholangitis (PBC), and Primary Sclerosing Cholangitis (PSC), and also cancers such as cholangiocarcinoma, affect tens of thousands of individuals in the UK each year. All biliary conditions require careful tracking of the structure and integrity of the biliary tree so that intervention can be carefully planned and with that, outcomes improved.

The current non-invasive gold-standard for assessment of the biliary tree is MRI-based Magnetic Resonance Cholangiopancreatography (MRCP). This method uses no contrast and takes up to 10 minutes to obtain within a normal scan event. However, there are several limitations to its use which include, images having great variability in quality and are used mainly for qualitative analysis. Using conventional MRCP a consultant can, depending on image quality; identify key structures, inform diagnosis, and give a general assessment on the health of the biliary tree structure. However, current MRCP imaging only allows limited quantitative assessment of the ducts. More extensive, objective quantification has the potential to dramatically improve the usability of MRCP imaging.With this in mind, imaging scientists at Perspectum Diagnostics have developed a hessian-based mathematical model to enhance conventional MRCP to a 3D geometric model of the biliary tree, 'Quantitative MRCP'. This enables quantitative measurement of bile duct width, orientation, branching point and curvative metrics.

The technology has been validated against 3D printed phantoms for accuracy, and early clinical research has demonstrated the technology has potential for clinical impact, with improvement in radiologist performance versus conventional non-enhanced MRCP imaging (Vikal et al 2017). Thus, further research into the technology and its viability as an enhancement to current procedure is necessary if it is to replace conventional MRCP as the primary method of non-invasive biliary assessment.

Integral to the development of any new technology, is demonstration of the repeatability and reproducibility of the method. This is the inter-examination variability in results. Quantitative MRCP aims to act as a tool to not only improve assessment of the current status of the biliary tree, but also act as a mechanism to track change within the ducts. Thus, it must be established that any change between scans is due to change in the physiology of the individual and not due to a quirk or fault of the technology.

The above will be tested by a series of scans performed on an individual over a short period of time, for which the condition of the biliary tree within that individual can be assumed to be constant. Between each scan, subject and coil repositioning will occur. The study will recruit a group of adult volunteers, from both diseased groups and healthy groups in order to achieve a range of physiological biliary metrics.

Quantitative MRCP is an MRI based method, requiring no contrast, however consuming a drink containing manganese improves the quality of MRCP images significantly (Frisch et al., 2017), and therefore patients are routinely asked to drink pineapple juice (naturally high in manganese) before having a clinical MRCP scan. At present, multiparametric MRI to assess the health of liver tissue is performed in a fasted state (Banerjee et al., 2014), however, in order to offer a comprehensive liver scan including both MRCP and multiparametric MRI in the same scan, it is important to understand whether consuming pineapple juice will affect the multiparametric MRI measurements of cT1, PDFF and T2*.

MRI is safe and non-invasive, with no known risks to patients as long as they are appropriately screened to ensure they have no contraindications to MRI (e.g.pacemaker, metal implant that is not certified as MR-safe).

Tarehe

Imethibitishwa Mwisho: 10/31/2018
Iliyowasilishwa Kwanza: 01/14/2019
Uandikishaji uliokadiriwa Uliwasilishwa: 01/16/2019
Iliyotumwa Kwanza: 01/17/2019
Sasisho la Mwisho Liliwasilishwa: 08/25/2019
Sasisho la Mwisho Lilichapishwa: 08/27/2019
Tarehe halisi ya kuanza kwa masomo: 07/18/2018
Tarehe ya Kukamilisha Msingi iliyokadiriwa: 09/07/2018
Tarehe ya Kukamilisha Utafiti: 03/07/2019

Hali au ugonjwa

Primary Sclerosing Cholangitis
Primary Biliary Cirrhosis
Gallstones
Liver Diseases

Uingiliaji / matibabu

Device: MRCP+

Awamu

-

Vikundi vya Arm

MkonoUingiliaji / matibabu
Biliary Conditions
Participants who have a history of a biliary tree related condition
Liver conditions
Participants who have a history of a non-biliary tree related liver condition
Healthy Volunteers
Participants who have do not have a diagnosed liver condition and are in general good health

Vigezo vya Kustahiki

Zama zinazostahiki Kujifunza 18 Years Kwa 18 Years
Jinsia Inastahiki KujifunzaAll
Njia ya sampuliNon-Probability Sample
Hupokea Wajitolea wa AfyaNdio
Vigezo

Inclusion Criteria:

- Persons over the age of 18 years

- Participant is willing and able to give informed consent for participation in the study.

- EITHER: Participant has a medical history of a liver or biliary tree related condition OR: Person is a healthy volunteer.

Exclusion Criteria:

- The participant may not enter the study if they have any contraindication to magnetic resonance imaging (inc pregnancy, extensive tattoos, pacemaker, shrapnel injury, severe claustrophobia).

- The participant may not enter the study if they have an allergy to pineapple juice.

- Any other cause, including a significant disease or disorder which, in the opinion of the investigator, may either put the participant at risk because of participation in the study, or may influence the participant's ability to participate in the study

Matokeo

Hatua za Matokeo ya Msingi

1. Assessment of Repeatability and Reproducibility of Quantitative MRCP [6 months]

Assessment of the variability of bile duct volume, bile duct diameter, branching points and locations of regions of variation in bile duct widths and percentages, as measured by quantitative MRCP between: A. Repeated scans of the same participant acquired under the same conditions B. Repeated scans of the same participant acquired on scanners which differ by field strength and/or manufacturer

Hatua za Matokeo ya Sekondari

1. Intra and Inter-operator reproducibility [6 months]

Statistical assessment of the agreement among quantitative MRCP analyses performed by both trained operators and expert radiologists.

2. Comparison of conventional MRCP and quantitative MRCP [6 months]

Statistical assessment of the agreement between quantitative MRCP analyses (performed by both trained operators and expert radiologists) and clinician ground truth (biliary tree assessment obtained by expert radiologists using conventional MRCP)

Hatua Nyingine za Matokeo

1. Assessment of the impact of pineapple juice consumption upon LiverMultiScan performance [6 months]

Statistical assessment of the agreement among cT1, PDFF and T2* measurements before and after consuming pineapple juice.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge