Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren 2008-May

[Pediatric bowel MRI--accelerated parallel imaging in a single breathhold].

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
C Hohl
D Honnef
G Krombach
C Ocklenburg
G Mühlenbruch
T G Wenzl
R W Günther
T Niendorf

Maneno muhimu

Kikemikali

OBJECTIVE

To compare highly accelerated parallel MRI of the bowel with conventional balanced FFE sequences in children with inflammatory bowel disease (IBD).

METHODS

20 children with suspected or proven IBD underwent MRI using a 1.5 T scanner after oral administration of 700 -1000 ml of a Mannitol solution and an additional enema. The examination started with a 4-channel receiver coil and a conventional balanced FFE sequence in axial (2.5 s/slice) and coronal (4.7 s/slice) planes. Afterwards highly accelerated (R = 5) balanced FFE sequences in axial (0.5 s/slice) and coronal (0.9 s/slice) were performed using a 32-channel receiver coil and parallel imaging (SENSE). Both receiver coils achieved a resolution of 0.88 x 0.88 mm with a slice thickness of 5 mm (coronal) and 6 mm (axial) respectively. Using the conventional imaging technique, 4 - 8 breathholds were needed to cover the whole abdomen, while parallel imaging shortened the acquisition time down to a single breathhold. Two blinded radiologists did a consensus reading of the images regarding pathological findings, image quality, susceptibility to artifacts and bowel distension. The results for both coil systems were compared using the kappa-(kappa)-coefficient, differences in the susceptibility to artifacts were checked with the Wilcoxon signed rank test. Statistical significance was assumed for p = 0.05.

RESULTS

13 of the 20 children had inflammatory bowel wall changes at the time of the examination, which could be correctly diagnosed with both coil systems in 12 of 13 cases (92 %). The comparison of both coil systems showed a good agreement for pathological findings (kappa = 0.74 - 1.0) and the image quality. Using parallel imaging significantly more artifacts could be observed (kappa = 0.47) without impairing the diagnostic impact. The comparison of the bowel distension showed no significant differences.

CONCLUSIONS

The highly accelerated parallel MRI using the SENSE technique and a 32-channel surface coil enables the examination of the entire bowel in a single breathhold without relevant restrictions in image quality and diagnostic impact.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge