Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Medical Screening 2001

Results from 10 years of breast screening in Wales.

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
H Fielder
C Rogers
K Gower-Thomas
I Monypenny
N Dallimore
D Brook
S Greening

Maneno muhimu

Kikemikali

OBJECTIVE

To present results from 10 years of breast screening in Wales, including rates of interval cancers.

METHODS

All women aged 50-64 years in Wales; approximately 250,000 in each screening round.

METHODS

Breast Test Wales (BTW) began mammographic screening in 1989 as part of the National Breast Screening Programme. Two view mammography was introduced at the inception of the Welsh programme for all prevalent screens. Single view mammography was subsequently performed for incident screens. Interval cancers were identified by matching details from the BTW administrative screening database with the BTW database of all incident breast cancers for residents in Wales.

RESULTS

For the first and second round prevalent screens, the cancer detection rate was 8.6 per 1000 and 7.4 per 1000 screened, respectively. The interval cancer rates following round one were 4.9 per 10,000 in the first 12 months, 9.0 per 10,000 between 12 and 24 months, and 11.6 per 10,000 between 24 and 36 months after screening. For the second round incident screens the detection rate was 4.6 per 1000 and the standardised detection ratio was 0.89, but the interval cancer rates in the first year after incident screens were not statistically different from those following prevalent screens. There was no change in the proportion of invasive breast cancers which were < 15 mm in diameter, or in the grades of invasive cancer between the first and second rounds, prevalent or incident screens.

CONCLUSIONS

Breast Test Wales has achieved the standards set by the National Health Service Breast Screening Programme. Taking two views at the prevalent screen gave high sensitivity and may have resulted in the low standardised detection ratio at subsequent incident screens.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge