Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Steroid Biochemistry and Molecular Biology 2003-Apr

Time-resolved fluoroimmunoassay for equol in plasma and urine.

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
Elke Brouwers
Rafaëlla L'homme
Nawaf Al-Maharik
Oldrich Lapcík
Richard Hampl
Kristiina Wähälä
Heikki Mikola
Herman Adlercreutz

Maneno muhimu

Kikemikali

We present a method for the determination of the isoflavan equol in plasma and urine. This estrogenic isoflavan, which is formed by the action of the intestinal microflora, may have higher biological activity than its precursor daidzein. High urinary excretion of equol has been suggested to be associated with a reduction in breast cancer risk. The method is based on time-resolved fluoroimmunoassay, using a europium chelate as a label. After synthesis of 4'-O-carboxymethylequol the compound is coupled to bovine serum albumin (BSA), then used as antigen to immunize rabbits. The tracer with the europium chelate is synthesized using the same 4'-O-derivative of equol. After enzymatic hydrolysis (urine) or enzymatic hydrolysis and ether extraction (plasma) the immunoassay is carried out. The antiserum cross-reacted to variable extent with some isoflavonoids. For the plasma method the cross-reactivity does not seem to influence the results, which were highly specific. The overestimation of the values using the urine method (164%) compared to the results obtained by a gas chromatography-mass spectrometry (GC-MS) method is probably due to some influence of the matrix on the signal, and interference of structurally related compounds. It is suggested that plasma assays are used but if urine samples are measured a formula has to be used to correct the values making them comparable to the GC-MS results. The correlation coefficients between the time-resolved fluoroimmunoassay (TR-FIA) methods and GC-MS methods were high; r-values for the plasma and urine method, were 0.98 and 0.91, respectively. The intra-assay coefficient of variation (CV%) for the TR-FIA plasma and urine results at three different concentrations vary between 5.5-6.5 and 3.4-6.9, respectively. The inter-assay CV% varies between 5.4-9.7 and 7.4-7.7, respectively. The working ranges of the plasma and urine assay are 1.27-512 and 1.9-512nmol/l, respectively.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge