Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Steroids 2000-Jun

Time-resolved fluoroimmunoassay of plasma daidzein and genistein.

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
G J Wang
O Lapcík
R Hampl
M Uehara
N Al-Maharik
K Stumpf
H Mikola
K Wähälä
H Adlercreutz

Maneno muhimu

Kikemikali

We present a method for the determination of the phytoestrogens daidzein and genistein in plasma (serum). These weakly estrogenic isoflavones occur in soybeans and in smaller amounts in some other beans and plants. It has been suggested that they may afford protection against prostate and breast cancer. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After synthesis of 4'-O-carboxymethyl-daidzein and 4'-O-carboxymethyl-genistein the compounds are coupled to bovine serum albumin (BSA), then used as antigens to immunize rabbits. The tracers with the europium chelate are synthesized using the same 4'-O-derivative of the isoflavones. After enzymatic hydrolysis and ether extraction the immunoassay is carried out using the VICTOR 1420 multilabel counter (Wallac Oy, Turku, Finland). The antisera cross-reacted to some extent with some isoflavonoids but not with flavonoids. The cross-reactivity seems not to influence the results, which were highly specific for both compounds. The correlation coefficients between the TR-FIA methods and the reference method based on isotope dilution gas chromatography-mass spectrometry were high; r-values were about 0.95-0.99 depending on concentration. The intra-assay coefficients of variation (CV%) for daidzein and genistein at three different concentrations vary 3.2-4.5 and 3.2-4.1, respectively. The inter-assay CVs vary 5.0-6.3 and 4.5-5.3, respectively. The working ranges of the daidzein and genistein assays are 1.0-216 and 1.7-370 nmol/l, respectively. The plasma values (n = 80) of daidzein and genistein are very low in Finnish subjects (mean for daidzein, 3.8+/-6.8 and for genistein, 3.2+/-7.6 nmol/l; median value for daidzein 1.5 and for genistein 1.4 nmol/l).

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge