Swahili
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Dermatitis : contact, atopic, occupational, drug

Volatility of fragrance chemicals: patch testing implications.

Watumiaji waliosajiliwa tu ndio wanaweza kutafsiri nakala
Ingia / Ingia
Kiungo kimehifadhiwa kwenye clipboard
Sarah J Gilpin
Xiaoying Hui
Howard I Maibach

Maneno muhimu

Kikemikali

BACKGROUND

Diagnostic and predictive patch testing to determine contact allergy due to fragrance materials requires applying a fixed dose of material to the skin. This dose can be affected by the volatile nature of fragrances; little data exist on how the loss of fragrance dose due to volatility affects patch testing.

OBJECTIVE

(1) To evaluate pH dependence and evaporation rates of two fragrance chemicals, geraniol, citronellol, and a common fragrance solvent, diethyl phthalate (DEP) and (2) Assess implications for predictive patch-testing methods for fragrances.

METHODS

pH analysis of each material at 1% for three values (4.0, 5.0, 7.0) was done over 40 hours. Volatility experiments for each material, nonradiolabeled and radiolabeled, were conducted over a 24-hour period, taking readings at six time points (5 minutes, 15 minutes, 40 minutes, 1 hour, 3 hours, and 24 hours).

RESULTS

Evaporation rates were not sensitive to pH shifts from 4.0 to 7.0. Evaporation rates for nonradiolabeled materials were low: after 24 hours, geraniol lost 8.9%, citronellol 27.0% and DEP 14.5%. The volatility data for radiolabeled materials demonstrated that geraniol loses up to 39% of its dose, citronellol loses up to 26%, and DEP up to 14% within 40 minutes.

CONCLUSIONS

The tendency of fragrance materials to evaporate can impact the dose being applied to the patch and therefore the result of the patch and ultimately the decision-making process regarding that fragrance material's safety. These data, developed with DEP, utilized in a predictive sensitization assay cannot be generalized.

Jiunge na ukurasa
wetu wa facebook

Hifadhidata kamili ya mimea ya dawa inayoungwa mkono na sayansi

  • Inafanya kazi katika lugha 55
  • Uponyaji wa mitishamba unaungwa mkono na sayansi
  • Kutambua mimea kwa picha
  • Ramani ya GPS inayoshirikiana
  • Soma machapisho ya kisayansi yanayohusiana na utafutaji wako
  • Tafuta mimea ya dawa na athari zao
  • Panga maslahi yako na fanya tarehe ya utafiti wa habari, majaribio ya kliniki na ruhusu

Andika dalili au ugonjwa na usome juu ya mimea ambayo inaweza kusaidia, chapa mimea na uone magonjwa na dalili ambazo hutumiwa dhidi yake.
* Habari zote zinategemea utafiti wa kisayansi uliochapishwa

Google Play badgeApp Store badge