Turkish
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
American Journal of Cardiovascular Drugs 2008

Fully biodegradable coronary stents : progress to date.

Sadece kayıtlı kullanıcılar makaleleri çevirebilir
Giriş yapmak kayıt olmak
Bağlantı panoya kaydedilir
Steve Ramcharitar
Patrick W Serruys

Anahtar kelimeler

Öz

The limitations of currently available metallic drug-eluting stents have renewed interest in biodegradable stents (BDS). Apart from removing the (offending) foreign material that may potentiate a thrombotic event, BDS have the advantage of avoiding 'full metal jackets,' and thus can preclude subsequent coronary surgery. In addition, they do not interfere with the diagnostic evaluation of non-invasive imaging such as cardiac magnetic resonance and CT. There are now several BDS in development or in clinical trials that incorporate a variety of biodegradable polymer technologies. Two broad categories of materials are generally used: those made from organic biopolymers and those made from corrodible metals. However, to date, none of the materials/stents tested have been able to establish a perfect balance between biocompatibility, the kinetics of degradation needed to maintain mechanical strength to limit recoil, and inflammation. However, studies, such as the ABSORB trial with the everolimus eluting poly-L-lactide stent, which demonstrated comparable restenotic rates with bare metallic stents and a low incidence of major adverse cardiac events (MACE) at 12 months of 3.3%, with only one patient having a non-Q-wave myocardial infarction and no target lesion revascularization, suggest that there has been significant progress with respect to the earlier prototypes. The acute recoil observed could potentially be addressed with the polytyrosine REVA stent currently being evaluated in the RESORB trial, which incorporates a novel locking mechanism within its design. Alternative BDS designs include the combination of an antiproliferative drug with endothelial progenitor cell capturing antibodies to facilitate epithelialization and/or dual eluting having, in addition to the antiproliferative drug, polymeric salicyclic acid to limit inflammation. Compared with biodegradable polymers, there are fewer metals used in the manufacture of BDS. The only metal BDS in trials is the Biotronik absorbable magnesium stent, which showed a MACE of 26.7% at 12 months without deaths, stent thrombosis, or acute myocardial infarction in the PROGRESS-AMS trial. Unlike magnesium stents, there has been little progress with iron stents, which remain in the pre-clinical phase, and this may be partly due to the longer degradation times needed and potential issues related with iron clearance.

Facebook sayfamıza katılın

Bilim tarafından desteklenen en eksiksiz şifalı otlar veritabanı

  • 55 dilde çalışır
  • Bilim destekli bitkisel kürler
  • Görüntüye göre bitki tanıma
  • Etkileşimli GPS haritası - bölgedeki bitkileri etiketleyin (yakında)
  • Aramanızla ilgili bilimsel yayınları okuyun
  • Şifalı bitkileri etkilerine göre arayın
  • İlgi alanlarınızı düzenleyin ve haber araştırmaları, klinik denemeler ve patentlerle güncel kalın

Bir belirti veya hastalık yazın ve yardımcı olabilecek bitkiler hakkında bilgi edinin, bir bitki yazın ve karşı kullanıldığı hastalıkları ve semptomları görün.
* Tüm bilgiler yayınlanmış bilimsel araştırmalara dayanmaktadır

Google Play badgeApp Store badge