中文(简体)
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Respiratory Care 2006-Feb

Practical problems with aerosol therapy in COPD.

只有注册用户可以翻译文章
登陆注册
链接已保存到剪贴板
Joseph L Rau

关键词

抽象

Inhaled aerosol drugs commonly used by patients with chronic obstructive pulmonary disease include short-acting and long-acting bronchodilators, as well as corticosteroids. These agents are available in a variety of inhaler devices, which include metered-dose inhalers (MDI), breath-actuated MDIs, nebulizers, and, currently, 5 different models of dry powder inhaler (DPI). There is evidence to suggest that multiple inhaler types cause confusion among patients and increase errors in patient use. Problems with MDIs include failure to coordinate inhalation with actuation of the MDI, inadequate breath-hold, and inappropriately fast inspiratory flow. Lack of a dose counter makes determining the number of remaining doses in an MDI problematic. Patient misuse of MDIs is compounded by lack of knowledge of correct use among health-care professionals. Several factors often seen with elderly patients have been identified as predictive of incorrect use of MDIs. These include mental-state scores, hand strength, and ideomotor dyspraxia. Holding chambers and spacers are partially intended to reduce the need for inhalation-actuation coordination with MDI use. However, such add-on devices can be subject to incorrect assembly. Possible delays between MDI actuation and inhalation, rapid inspiration, chamber electrostatic charge, and firing multiple puffs into the chamber can all reduce the availability of inhaled drug. Because they are breath-actuated, DPIs remove the need for inhalation-actuation synchrony, but there is evidence that patient errors in use of DPIs may be similar to those with MDIs. One of the biggest problems is loading and priming the DPI for use, and this may be due to the fact that every DPI model in current use is different. Medical personnel's knowledge of correct DPI use has also been shown to be lacking. The optimum inhalation profiles are different for the various DPIs, but, generally, chronic obstructive pulmonary disease patients have been shown to achieve a minimum therapeutic dose, although the inhaled amount may be suboptimal. A limitation of DPIs that have multidose powder reservoirs (eg, the Turbuhaler) is ambient humidity, which can reduce the released dose. Small-volume nebulizers are limited by bulk, treatment time, and variable performance, but are easy for patients to use. Important features identified by patients for an ideal inhaler are ease of use during an attack, dose counter, and general ease of use and learning. A breath-actuated-pMDI, such as the Autohaler, ranked at the top of inhaler preference in a study of 100 patients with airflow obstruction, compared to DPIs and MDIs. Short of a universal simple inhaler, patient and caregiver education remains the best solution to correct patient errors in use.

加入我们的脸书专页

科学支持的最完整的草药数据库

  • 支持55种语言
  • 科学支持的草药疗法
  • 通过图像识别草药
  • 交互式GPS地图-在位置标记草药(即将推出)
  • 阅读与您的搜索相关的科学出版物
  • 通过药效搜索药草
  • 组织您的兴趣并及时了解新闻研究,临床试验和专利

输入症状或疾病,并阅读可能有用的草药,输入草药并查看所使用的疾病和症状。
*所有信息均基于已发表的科学研究

Google Play badgeApp Store badge